MAIFI
The Momentary Average Interruption Frequency Index (MAIFI) is a reliability index used by electric power utilities.[src] MAIFI is the average number of momentary interruptions that a customer would experience during a given period (typically a year).[src] Electric power utilities may define momentary interruptions differently, with some considering a momentary interruption to be an outage of less than 1 minute in duration while others may consider a momentary interruption to be an outage of less than 5 minutes in duration.[src]
The Momentary Average Interruption Frequency Index (MAIFI) is a reliability index used by electric power utilities.[src] MAIFI is the average number of momentary interruptions that a customer would experience during a given period (typically a year).[src] Electric power utilities may define momentary interruptions differently, with some considering a momentary interruption to be an outage of less than 1 minute in duration while others may consider a momentary interruption to be an outage of less than 5 minutes in duration.[src] ==Calculation== MAIFI is calculated as \mbox{MAIFI} = \frac{\mbox{total number of customer interruptions less than the defined time}}{\mbox{total number of customers served}} ==Reporting== MAIFI has tended to be less reported than other reliability indicators, such as SAIDI, SAIFI, and CAIDI.[src] However, MAIFI is useful for tracking momentary power outages, or "blinks," that can be hidden or misrepresented by an overall outage duration index like SAIDI or SAIFI.[src] ==Causes== Momentary power outages are often caused by transient faults, such as lightning strikes or vegetation contacting a power line, and many utilities use reclosers to automatically restore power quickly after a transient fault has cleared.[src] ==Comparisons== MAIFI is specific to the area ( power utility, state, region, county, power line, etc.[src] ) because of the many variables that affect the measure: high/low lightning, number & type of trees, high/low winds, etc.[src] Therefore, comparing MAIFI of one power utility to another is not valid and should not be used in this type of benchmarking.[src] It also is difficult to compare this measure of reliability within a single utility.[src] One year may have had an unusually high number of thunderstorms and thus skew any comparison to another year's MAIFI.[src] ==References==[src]
15 sentences · 15 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"MAIFI." encyclopegia.org, 2023, https://encyclopegia.org/wiki/maifi. Accessed 27 November 2026.
Chicago
"MAIFI." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/maifi.
APA
encyclopegia.org. (2023). MAIFI. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/maifi
Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON