encyclopegia.org

Matrix isolation

Matrix isolation is an experimental technique used in chemistry and physics.[src] It generally involves a material being trapped within an unreactive matrix.[src] A host matrix is a continuous solid phase in which guest particles (atoms, molecules, ions, etc.) are embedded.[src] The guest is said to be isolated within the host matrix.[src] Initially the term matrix-isolation was used to describe the placing of a chemical species in any unreactive material, often polymers or resins, but more recently has referred specifically to gases in low-temperature solids.[src] A typical matrix isolation experiment involves a guest sample being diluted in the gas phase with the host material, usually a noble gas or nitrogen.[src] This mixture is then deposited on a window that is cooled to below the melting point of the host gas.[src] The sample may then be studied using various spectroscopic procedures.[src]

Matrix isolation is an experimental technique used in chemistry and physics.[src] It generally involves a material being trapped within an unreactive matrix.[src] A host matrix is a continuous solid phase in which guest particles (atoms, molecules, ions, etc.) are embedded.[src] The guest is said to be isolated within the host matrix.[src] Initially the term matrix-isolation was used to describe the placing of a chemical species in any unreactive material, often polymers or resins, but more recently has referred specifically to gases in low-temperature solids.[src] A typical matrix isolation experiment involves a guest sample being diluted in the gas phase with the host material, usually a noble gas or nitrogen.[src] This mixture is then deposited on a window that is cooled to below the melting point of the host gas.[src] The sample may then be studied using various spectroscopic procedures.[src] ==Experimental setup== The transparent window, on to which the sample is deposited, is usually cooled using a compressed helium or similar refrigerant.[src] Experiments must be performed under a high vacuum to prevent contaminants from unwanted gases freezing to the cold window.[src] Lower temperatures are preferred, due to the improved rigidity and "glassiness" of the matrix material.[src] Noble gases such as argon are used not just because of their unreactivity but also because of their broad optical transparency in the solid state.[src] Mono-atomic gases have relatively simple face-centered cubic (fcc) crystal structure, which can make interpretations of the site occupancy and crystal-field splitting of the guest easier.[src] In some cases a reactive material, for example, methane, hydrogen or ammonia, may be used as the host material so that the reaction of the host with the guest species may be studied.[src] Using the matrix isolation technique, short-lived, highly-reactive species such as radical ions and reaction intermediates may be observed and identified by spectroscopic means.[src] For example, the solid noble gas krypton can be used to form an inert matrix within which a reactive F 3 − ion can sit in chemical isolation.[src] The reactive species can either be generated outside (before deposition) the apparatus and then be condensed, inside the matrix (after deposition) by irradiating or heating a precursor, or by bringing together two reactants on the growing matrix surface.[src] For the deposition of two species it can be crucial to control the contact time and temperature.[src] In twin jet deposition the two species have a much shorter contact time (and lower temperature) than in merged jet.[src] With concentric jet the contact time is adjustable.[src] ==Spectroscopy== Within the host matrix, the rotation and translation of the guest particle is usually inhibited.[src] Therefore, the matrix isolation technique may be used to simulate a spectrum of a species in the gas phase without rotational and translational interference.[src] The low temperatures also help to produce simpler spectra, since only the lower electronic and vibrational quantum states are populated.[src] Especially infrared (IR) spectroscopy, which is used to investigate molecular vibration, benefits from the matrix isolation technique.[src] For example, in the gas-phase IR spectrum of fluoroethane some spectral regions are very difficult to interpret, as vibrational quantum states heavily overlap with multiple rotational-vibrational quantum states.[src] When fluoroethane is isolated in argon or neon matrices at low temperatures, the rotation of the fluoroethane molecule is inhibited.[src] Because rotational-vibrational quantum states are quenched in the matrix isolation IR spectrum of fluoroethane, all vibrational quantum states can be identified.[src] This is especially useful for the validation of simulated infrared spectra that can be obtained from computational chemistry.[src] ==History== Matrix isolation has its origins in the first half of the 20th century with the experiments by photo-chemists and physicists freezing samples in liquefied gases.[src] The earliest isolation experiments involved the freezing of species in transparent, low temperature organic glasses, such as EPA (ether/isopentane/ethanol 5:5:2).[src] The modern matrix isolation technique was developed extensively during the 1950s, in particular by George C.[src] Pimentel.[src] He initially used higher-boiling inert gases like xenon and nitrogen as the host material, and is often said to be the "father of matrix isolation".[src] Laser vaporization in matrix isolation spectroscopy was first brought about in 1969 by Schaeffer and Pearson using a yttrium aluminum garnet (YAG) laser to vaporize carbon which reacted with hydrogen to produce acetylene.[src] They also showed that laser-vaporized boron would react with HCl to create BCl .[src] In the 1970s, Koerner von Gustorf's lab used the technique to produce free metal atoms which were then deposited with organic substrates for use in organometallic chemistry.[src] Spectroscopic studies were done on reactive intermediates in around the early 1980s by Bell Labs.[src] They used laser-induced fluorescence to characterize multiple molecules like SnBi and SiC .[src] Smalley's group employed the use of this method with time-of-flight mass spectrometry by analyzing Al clusters.[src] With the work of chemists like these, laser-vaporization in matrix isolation spectroscopy rose in popularity due to its ability to generate transients involving metals, alloys and semi-conductor molecules and clusters.[src] ==See also== Host–guest chemistry Inert gas Van der Waals interactions Radicals ==References==[src]

49 sentences · 49 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Matrix isolation." encyclopegia.org, 2026, https://encyclopegia.org/wiki/matrix-isolation. Accessed 28 November 2026.

Chicago

"Matrix isolation." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/matrix-isolation.

APA

encyclopegia.org. (2026). Matrix isolation. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/matrix-isolation

Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

diode matrix

stub · references available

identity matrix

stub · references available

adjugate matrix

stub · references available

matrix mechanics

stub · references available

Hilbert matrix

stub · references available

Tranquil Isolation

stub · references available

matrix

stub · references available

product-market growth matrix

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1335022755 · 0.5 · snapshot enwiki-001335022755

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.