Microcrystal electron diffraction
Microcrystal electron diffraction, or MicroED, is a CryoEM method that was developed by the Gonen laboratory in late 2013 at the Janelia Research Campus of the Howard Hughes Medical Institute.[src] MicroED is a form of electron crystallography where thin 3D crystals are used for structure determination by electron diffraction.[src] Prior to this demonstration, macromolecular (protein) electron crystallography was mainly used on 2D crystals, for example.[src] The method is one of several modern versions of approaches to determine atomic structures using electron diffraction first demonstrated for the positions of hydrogen atoms in NH4Cl crystals by W.[src] E.[src] Laschkarew and I.[src] D.[src] Usykin in 1933, which has since been used for surfaces, via precession electron diffraction, with much of the early work described in the work of Boris Vainshtein and Douglas L.[src] Dorset.[src] The method was developed for structure determination of proteins from nanocrystals that are typically not suitable for X-ray diffraction because of their size.[src] Crystals that are one billionth the size needed for X-ray crystallography can yield high quality data.[src] The samples are frozen hydrated as for all other CryoEM modalities but instead of using the transmission electron microscope (TEM) in imaging mode one uses it in diffraction mode with a low electron exposure (typically − /Å 2 /s).…[src]
Microcrystal electron diffraction, or MicroED, is a CryoEM method that was developed by the Gonen laboratory in late 2013 at the Janelia Research Campus of the Howard Hughes Medical Institute.[src] MicroED is a form of electron crystallography where thin 3D crystals are used for structure determination by electron diffraction.[src] Prior to this demonstration, macromolecular (protein) electron crystallography was mainly used on 2D crystals, for example.[src] The method is one of several modern versions of approaches to determine atomic structures using electron diffraction first demonstrated for the positions of hydrogen atoms in NH4Cl crystals by W.[src] E.[src] Laschkarew and I.[src] D.[src] Usykin in 1933, which has since been used for surfaces, via precession electron diffraction, with much of the early work described in the work of Boris Vainshtein and Douglas L.[src] Dorset.[src] The method was developed for structure determination of proteins from nanocrystals that are typically not suitable for X-ray diffraction because of their size.[src] Crystals that are one billionth the size needed for X-ray crystallography can yield high quality data.[src] The samples are frozen hydrated as for all other CryoEM modalities but instead of using the transmission electron microscope (TEM) in imaging mode one uses it in diffraction mode with a low electron exposure (typically − /Å 2 /s).[src] The nano crystal is exposed to the diffracting beam and continuously rotated while diffraction is collected on a fast camera as a movie.[src] MicroED data is then processed using software for X-ray crystallography for structure analysis and refinement.[src] The hardware and software used in a MicroED experiment are standard and broadly available.[src] ==Experimental setup== Detailed protocols for setting up the electron microscope and for data collections have been published.[src] ====Still diffraction==== The initial proof of concept publication on MicroED used lysozyme crystals.[src] Up to 90 degrees of data were collected from a single nano crystal, with discrete 1 degree steps between frames.[src] Each diffraction pattern was collected with an ultra-low dose rate of ~0.01 e − /Å 2 /s.[src] Data from 3 crystals was merged to yield a 2.9Å resolution structure with good refinement statistics, enabling determination of the structure of a dose-sensitive protein from 3D microcrystals in cryogenic conditions.[src] ====Continuous rotation==== MicroED uses continuous rotation during the data collection scheme.[src] Here the crystal is slowly rotated in a single direction while diffraction is recorded on a fast camera as a movie.[src] This led to several improvements in data quality and allowed data processing using standard X-ray crystallographic software.[src] Continuous rotation MicroED improves sampling of reciprocal space.[src] ===Data processing=== Detailed protocols for MicroED data processing have been published.[src] When MicroED data is collected using continuous stage rotation, standard crystallography software can be used.[src] ==Comparison with other electron diffraction methods== Other electron diffraction methods that have been developed and demonstrated to work include Automated Diffraction Tomography (ADT) and Rotation Electron Diffraction (RED ).[src] These methods differ slightly from MicroED: In ADT discrete steps of goniometer tilt are used to cover reciprocal space in combination with beam precession to reduce dynamical diffraction effects.[src] ADT uses hardware and software for precession and scanning transmission electron microscopy for crystal tracking.[src] RED is done in TEM but the goniometer is tilted in discrete steps and beam tilting is used to fill in the gaps.[src] Software is used to process ADT and RED data.[src] Video interview about the development of MicroED and its applications The Janelia Archives background on MicroED Background and publications on MicroED from the Gonen Laboratory[src]
44 sentences · 44 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Microcrystal electron diffraction." encyclopegia.org, 2026, https://encyclopegia.org/wiki/microcrystal-electron-diffraction. Accessed 27 November 2026.
Chicago
"Microcrystal electron diffraction." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/microcrystal-electron-diffraction.
APA
encyclopegia.org. (2026). Microcrystal electron diffraction. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/microcrystal-electron-diffraction
Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON