Microfiltration
Microfiltration is a type of physical filtration process where a contaminated fluid is passed through a special pore-sized membrane filter to separate microorganisms and suspended particles from process liquid. It is commonly used in conjunction with various other separation processes such as ultrafiltration and reverse osmosis to provide a product stream which is free of undesired contaminants.
Microfiltration is a type of physical filtration process where a contaminated fluid is passed through a special pore-sized membrane filter to separate microorganisms and suspended particles from process liquid. It is commonly used in conjunction with various other separation processes such as ultrafiltration and reverse osmosis to provide a product stream which is free of undesired contaminants. ==General principles== Microfiltration usually serves as a pre-treatment for other separation processes such as ultrafiltration, and a post-treatment for granular media filtration. The typical particle size used for microfiltration ranges from about 0.1 to 10 μm. In terms of approximate molecular weight these membranes can separate macromolecules of molecular weights generally less than 100,000 g/mol. The filters used in the microfiltration process are designed to prevent particles such as sediment, algae, protozoa or large bacteria from passing through the membrane. More microscopic, atomic or ionic materials such as water (H 2 O), monovalent species such as Sodium (Na + ) or Chloride (Cl − ) ions, dissolved or natural organic matter, and small colloids and viruses will still be able to pass through the filter. The suspended liquid is passed through at a relatively high velocity of around 1–3 m/s and at low to moderate pressures (around 100–400 kPa) parallel or tangential to the semi-permeable membrane in a sheet or tubular form. A pump is commonly fitted onto the processing equipment to allow the liquid to pass through the membrane filter. There are also two pump configurations, either pressure driven or vacuum. A differential or regular pressure gauge is commonly attached to measure the pressure drop between the outlet and inlet streams. See Figure 1 for a general setup. The most abundant use of microfiltration membranes are in the water, beverage and bio-processing industries (see below). The exit process stream after treatment using a micro-filter has a recovery rate which generally ranges to about 90–98 %. ==Range of applications== ===Water treatment=== Perhaps the most prominent use of microfiltration membranes pertains to the treatment of potable water supplies. The membranes are a key step in the primary disinfection of the intake water stream. Such a stream might contain pathogens such as the protozoa Cryptosporidium and Giardia lamblia which are responsible for numerous disease outbreaks. Both species show a gradual resistance to traditional disinfectants (i.e. chlorine). The use of MF membranes presents a physical means of separation (a barrier) as opposed to a chemical alternative. In that sense, both filtration and disinfection take place in a single step, negating the extra cost of chemical dosage and the corresponding equipment (needed for handling and storage). Similarly, the MF membranes are used in secondary wastewater effluents to remove turbidity but also to provide treatment for disinfection. At this stage, coagulants (iron or aluminum) may potentially be added to precipitate species such as phosphorus and arsenic which would otherwise have been soluble. ===Sterilization=== Another crucial application of MF membranes lies in the cold sterilisation of beverages and pharmaceuticals. Historically, heat was used to sterilize refreshments such as juice, wine and beer in particular, however a palatable loss in flavour was clearly evident upon heating. Similarly, pharmaceuticals have been shown to lose their effectiveness upon heat addition. MF membranes are employed in these industries as a method to remove bacteria and other undesired suspensions from liquids, a procedure termed as 'cold sterilisation', which negate the use of heat. ===Petroleum refining=== Furthermore, microfiltration membranes are finding increasing use in areas such as petroleum refining, in which the removal of particulates from flue gases is of particular concern. The key challenges/requirements for this technology are the ability of the membrane modules to withstand high temperatures (i.e. maintain stability), but also the design must be such to provide a very thin sheeting (thickness v = \frac{D^2*\Delta P}{32*\mu *L} Transmembrane Pressure (TMP) The transmembrane pressure (TMP) is defined as the mean of the applied pressure from the feed to the concentrate side of the membrane subtracted by the pressure of the permeate. This is applied to dead-end filtration mainly and is indicative of whether a system is fouled sufficiently to warrant replacement. v = \frac{P_F + P_C}{2} - P_P Where P_f is the pressure on the Feed Side P_c is the pressure of the Concentrate P_p is the pressure of the Permeate Permeate Flux The permeate flux in microfiltration is given by the following relation, based on Darcy's Law J_v = \frac{1}{A_M}*\frac{dV}{dt} = \frac{\Delta P}{\mu *(R_u + R_c)} Where R_u = Permeate membrane flow resistance ( m-1 ) R_c = Permeate cake resistance ( m-1 ) μ = Permeate viscosity (kg m-1 s-1) ∆P = Pressure Drop between the cake and membrane The cake resistance is given by: R_c= r*\frac{V_S}{A_m} Where r = Specific cake resistance (m-2) Vs = Volume of cake (m3) AM = Area of membrane (m2) For micron sized particles the Specific Cake Resistance is roughly. r= \frac{180*(1-\epsilon)}{\epsilon^3*d_s^2 } Where ε = Porosity of cake (unitless) d_s = Mean particle diameter (m) Rigorous design equations To give a better indication regarding the exact determination of the extent of the cake formation, one-dimensional quantitative models have been formulated to determine factors such as Complete Blocking (Pores with an initial radius less than the radius of the pore) Standard Blocking Sublayer Formation Cake Formation See External Links for further details ==Environmental issues, safety and regulation== Although environmental impacts of membrane filtration processes differ according to the application, a generic method of evaluation is the life-cycle assessment (LCA), a tool for the analysis of the environmental burden of membrane filtration processes at all stages and accounts for all types of impacts upon the environment including emission to land, water and air. In regards to microfiltration processes, there are a number of potential environmental impacts to be considered. They include global warming potential, photo-oxidant formation potential, eutrophication potential, human toxicity potential, freshwater ecotoxicity potential, marine ecotoxicity potential and terrestrial ecotoxicity potential. In general, the potential environmental impact of the process is largely dependent on flux and the maximum transmembrane pressure, however other operating parameters remain a factor to be considered. A specific comment on which exact combination of operational condition will yield the lowest burden on the environment cannot be made as each application will require different optimisations. In a general sense, membrane filtration processes are relative "low risk" operations, that is, the potential for dangerous hazards are small. There are, however several aspects to be mindful of. All pressure-driven filtration processes including microfiltration requires a degree of pressure to be applied to the feed liquid stream as well as imposed electrical concerns. Other factors contributing to safety are dependent on parameters of the process. For example, processing dairy product will lead to bacteria formations that must be controlled to comply with safety and regulatory standards. ==Comparison with similar processes== Membrane microfiltration is fundamentally the same as other filtration techniques utilising a pore size distribution to physically separate particles. It is analogous to other technologies such as ultra/nanofiltration and reverse osmosis, however, the only difference exists in the size of the particles retained, and also the osmotic pressure. The main of which are described in general below: ===Ultrafiltration=== Ultrafiltration membranes have pore sizes ranging from 0.1 μm to 0.01 μm and are able to retain proteins, endotoxins, viruses and silica. UF has diverse applications which span from waste water treatment to pharmaceutical applications. ===Nanofiltration=== Nanofiltration membranes have pores sized from 0.001 μm to 0.01 μm and filters multivalent ions, synthetic dyes, sugars and specific salts. As the pore size drops from MF to NF, the osmotic pressure requirement increases. ===Reverse osmosis=== Reverse osmosis (RO) is the finest separation membrane process available, pore sizes range from 0.0001 μm to 0.001 μm. Reverse osmosis is able to retain almost all molecules except for water, and due to the size of the pores, the required osmotic pressure is significantly greater than that for microfiltration. Both reverse osmosis and nanofiltration are fundamentally different from microfiltration since the flow goes against the concentration gradient, because those systems use pressure as a means of forcing water to go from low osmotic pressure to high osmotic pressure. ==Recent developments== Recent advances in MF have focused on manufacturing processes for the construction of membranes and additives to promote coagulation and therefore reduce the fouling of the membrane. Since MF, UF, NF and RO are closely related, these advances are applicable to multiple processes and not MF alone. Recently studies have shown dilute KMnO 4 preoxidation combined FeCl 3 is able to promote coagulation, leading to decreased fouling, in specific the KMnO 4 preoxidation exhibited an effect which decreased irreversible membrane fouling. Similar research has been done into the construction high flux poly(trimethylene terephthalate) (PTT) nanofiber membranes, focusing on increased throughput. Specialised heat treatment and manufacturing processes of the membrane's internal structure exhibited results indicating a 99.6% rejection rate of TiO 2 particles under high flux. The results indicate that this technology may be applied to existing applications to increase their efficiency via high flux membranes. ==See also== ==References== ==External links== Polyakov, Yu, Maksimov, D, & Polyakov, V, 1998 'On the Design of Microfilters' Theoretical Foundations of Chemical Engineering, Vol. 33, No. 1, 1999. Layson A, 2003, Microfiltration – Current Know-how and Future Directions, IMSTEC, accessed 1 October 2013 https://web.archive.org/web/20131015111520/http://www.ceic.unsw.edu.au/centers/membrane/imstec03/content/papers/MFUF/imstec152.pdf> University of New South Wales Chemical Engineering Website.
References
No reference rows published for this article.
Cite this article
MLA
"Microfiltration." encyclopegia.org, 2026, https://encyclopegia.org/wiki/microfiltration. Accessed 24 November 2026.
Chicago
"Microfiltration." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/microfiltration.
APA
encyclopegia.org. (2026). Microfiltration. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/microfiltration
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON