MOWChIP-seq
MOWChIP-seq (Microfluidic Oscillatory Washing–based Chromatin ImmunoPrecipitation followed by sequencing) is a microfluidic technology used in molecular biology for profiling genome-wide histone modifications and other molecular bindings using as few as 30-100 cells per assay.[src] MOWChIP-seq is a special type of ChIP-seq assay designed for low-input and high-throughput assays.[src] The overall process of MOWChIP-seq is similar to that of conventional ChIP-seq assay except that the chromatin immunoprecipitation (ChIP) and washing steps occur in a small microfluidic chamber.[src] MOWChIP-seq takes advantage of the capability of microfluidics for manipulating micrometer-sized beads.[src] In the process, a packed bed of beads is formed to drastically increase the adsorption efficiency of chromatin fragments.[src] An automated oscillatory washing is then used to remove nonspecific binding and impurity from the bead surface.[src] Initial version of MOWChIP device contained only one microfluidic chamber.[src] In the more recent demonstration, semi-automated MOWChIP device for running 8 parallel assays was presented.[src]
MOWChIP-seq (Microfluidic Oscillatory Washing–based Chromatin ImmunoPrecipitation followed by sequencing) is a microfluidic technology used in molecular biology for profiling genome-wide histone modifications and other molecular bindings using as few as 30-100 cells per assay.[src] MOWChIP-seq is a special type of ChIP-seq assay designed for low-input and high-throughput assays.[src] The overall process of MOWChIP-seq is similar to that of conventional ChIP-seq assay except that the chromatin immunoprecipitation (ChIP) and washing steps occur in a small microfluidic chamber.[src] MOWChIP-seq takes advantage of the capability of microfluidics for manipulating micrometer-sized beads.[src] In the process, a packed bed of beads is formed to drastically increase the adsorption efficiency of chromatin fragments.[src] An automated oscillatory washing is then used to remove nonspecific binding and impurity from the bead surface.[src] Initial version of MOWChIP device contained only one microfluidic chamber.[src] In the more recent demonstration, semi-automated MOWChIP device for running 8 parallel assays was presented.[src]
16 sentences · 16 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"MOWChIP-seq." encyclopegia.org, 2022, https://encyclopegia.org/wiki/mowchip-seq. Accessed 26 November 2026.
Chicago
"MOWChIP-seq." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/mowchip-seq.
APA
encyclopegia.org. (2022). MOWChIP-seq. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/mowchip-seq
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON