Multiple electrode aggregometry
Multiplate multiple electrode aggregometry (MEA) is a test of platelet function in whole blood.[src] The test can be used to assess platelet function, monitor antiplatelet therapy, and is also investigated as a potential predictor of transfusion requirements and bleeding risk in cardiac surgery.[src]
Multiplate multiple electrode aggregometry (MEA) is a test of platelet function in whole blood.[src] The test can be used to assess platelet function, monitor antiplatelet therapy, and is also investigated as a potential predictor of transfusion requirements and bleeding risk in cardiac surgery.[src] ==Instrument== The Multiplate MEA Analyzer (Roche Diagnostics International Ltd) has 5 channels for simultaneous measurement of several samples or agonists.[src] The instrument detects change in electrical impedance when platelets aggregate on metal electrodes in the test cuvette.[src] Each cuvette contains two pairs of sensor electrodes, each of which measures the change in impedance.[src] The duplicate sensors serve as an integrated quality control, and the analysis is accepted if the correlation coefficient of the measurements is greater than 0.98.[src] The difference of each curve from the mean curve is also calculated, and a difference of less than 20% is accepted.[src] The test cuvettes also contain a teflon coated magnetic stirring bar.[src] The increase in impedance as aggregation occurs is transformed into aggregation units (AU) and plotted against time on the computer screen.[src] ==Sample== The manufacturer recommends the use of hirudin as anticoagulant for samples to be tested, but studies have shown that heparin is a good alternative.[src] 300 μL of blood is needed for each analysis, and is diluted with the same amount of saline.[src] After pipetting blood and saline into the cuvette, the test is incubated for three minutes before the chosen agonist is added.[src] The test is then started, and platelet aggregation is recorded at approximately 0.5 second intervals for six minutes.[src] Three parameters are calculated: aggregation, velocity and area under the curve (AUC).[src] Aggregation (in AU) is the maximum height of the aggregation curve, and velocity (in AU/min) is the maximum slope of the curve.[src] AUC is the most important parameter.[src] It is recorded in Units (U), and is affected by both the height and the slope of the aggregation curve, and is the best overall measure of platelet activity.[src] ==Multiplate Tests/Reagents== ===ADPtest=== Adenosine diphosphate (ADP) is a platelet agonist.[src] When it is added to saline-diluted whole blood in the test cuvette, it stimulates the ADP receptors on platelets, activating the platelets.[src] The activation of the platelets leads to shape change and degranulation, and the released content of the granules further activates the platelets.[src] Activation also induces a conformational change in the glycoprotein IIb/IIIa (GPIIb/IIIa) receptor, giving it high affinity for fibrinogen.[10] Binding of fibrinogen to GPIIb/IIIa receptors leads to platelet-to-platelet bridges and results in platelet aggregation.[10] Antiplatelet drugs like clopidogrel and prasugrel irreversibly inhibit the ADP receptor P2Y12, leading to a decreased ADP-induced platelet aggregation.[src] Drugs that inhibit the GPIIb/IIIa receptor, e.g.[10] eptifibatide, can also reduce or eliminate the ADP-induced platelet response.[src] ===ASPItest=== In the ASPItest arachidonic acid is added to the saline-diluted blood sample.[src] Arachidonic acid is converted to prostaglandin H2 (PGH2) by cyclooxygenase-1 (COX1), and PGH2 is then converted to thromboxane A2 (TXA2) by thromboxane synthase.[src] TXA2 increases platelet aggregation, promotes degranulation and stimulates platelet activation.[src] Inhibition of COX1, as with acetylsalicylic acid, and inhibition or absence of GPIIb/IIIa receptor, as seen in Glanzmann's thrombasthenia, will reduce platelet aggregation in response to arachidonic acid.[10] ===COLtest=== Collagen is added to the sample-saline mix, and binds to collagen-receptors on platelets.[src] This leads to a release of arachidonic acid, which is converted to the potent platelet activator TXA2.[src] COLtest is sensitive to inhibition of COX1 and GPIIb/IIIa and to Glanzmann's thrombasthenia.[10] ===RISTOtest=== Ristocetin forms complexes with von Willebrand factor (vWF) that bind to the glycoprotein Ib (GP1b) receptors on platelets, causing platelet activation and aggregation.[src] Reduced or absent aggregation in response to ristocetin can be caused by a lack of or reduction of vWF, as seen in von Willebrand disease (vWD), or absence or reduction in numbers of GP1b receptors, as in Bernard–Soulier syndrome (BSS).[src] RISTOtest can be performed in two concentrations; RISTOhigh and RISTOlow.[src] In RISTOhigh, a ristocetin concentration of 0,77 mg/mL is applied.[src] This normally induces a strong platelet aggregation, and low or absent aggregation can be caused by the earlier mentioned conditions vWD and BSS.[src] In RISTOlow, the ristocetin concentration is just 0,2 mg/mL, and at a level that does not normally induce a strong aggregation response.[src] This test can detect if vWF shows a stronger than normal tendency to aggregate platelets, which can be seen in a subtype of vWD called vWDIIb.[src] ===TRAPtest=== Thrombin receptor activating peptide-6 (TRAP-6) activates platelets through the thrombin receptor protease activated receptor-1 (PAR-1).[src] Binding of TRAP-6 to PAR-1 causes a conformational change in the GPIIb/IIIa receptors on platelets, giving them high affinity for fibrinogen.[10] Fibrinogen then binds to the receptors, crosslinking several platelets and causing aggregation.[src] Aggregation in TRAPtest may be reduced or absent in Glanzmann's thrombasthenia, where GPIIb/IIIa receptors are few or absent, or if the patient is taking a GPIIb/IIIa antagonist.[10] Traptest has only minor sensitivity for inhibition of COX1 and ADP-receptors.[src] ===ASA Reagent=== Adding ASA (acetylsalicylic acid) reagent to a blood sample reduces the aggregation responses in ASPItest and COLtest.[9] ASA irreversibly inhibits COX1 in platelets, thereby inhibiting the production of TXA2.[src] The ASA Reagent is used as a quality control in the platelet function testing with Multiplate, allowing the assessment of abnormal platelet responses in ASPItest and COLtest.[9] ===GPIIb/IIIa Antagonist Reagent=== This reagent is used as a quality control in Multiplate platelet function testing.[10] The GPIIb/IIIa antagonist blocks the binding of fibrinogen to the GPIIb/IIIa receptors, preventing the formation of platelet-fibrinogen bonds and resulting in significantly reduced platelet aggregation in response to all agonists.[10] The antagonist reagent is used together with TRAP-test, and allows assessment of a positive control.[10] ===Prostaglandin E1 Reagent=== Prostaglandin E1 (PGE1) is a platelet inhibitor that causes an increase in cyclic adenosine monophosphate (cAMP) in platelets by stimulating adenylyl cyclase activity.[2] cAMP is an intracellular signaling molecule, and the increase in cAMP inhibits calcium mobilization and platelet aggregation induced by activation of the ADP receptor P2Y1.[src] Activation of the P2Y1 receptor initiates platelet aggregation in response to ADP.[src] The P2Y1 receptor is required for ADP-induced platelet activation, but is not sufficient for a full platelet aggregation in response to ADP.[src] cAMP inhibits platelet aggregation, and decreased amounts of cAMP in platelets lead to platelet aggregation.[src] The PGE1 reagent is used together with the ADP test for two purposes: the assessment of ADP high sensitivity (HS) and of positive controls of the ADPtest.[2] When a small amount of PGE1 (20 μL) is added to the ADPtest, it induces a moderat inhibition of aggregation in normal samples, but greatly increases the sensitivity of platelets to inhibition by clopidogrel.[src] This is why the modified test is called "High Sensitivity".[src] Adding 50 μL of PGE1 to the ADPtest leads to a strong inhibition of ADP induced aggregation, and is used for assessment of positive controls of the ADPtest.[src] ==References==[src]
62 sentences · 62 cited inline · 10 references stored
References
- Ranucci, Marco. Point-of-Care Tests for Severe Hemorrhage: A Manual for Diagnosis and Treatment . · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "Ranucci, Marco. Point-of-Care Tests for Severe Hemorrhage: A Manual for Diagnosis and Treatment ." Ranucci, Marco. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "Ranucci, Marco. Point-of-Care Tests for Severe Hemorrhage: A Manual for Diagnosis and Treatment ." Ranucci, Marco. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA Ranucci, Marco. (2026). Ranucci, Marco. Point-of-Care Tests for Severe Hemorrhage: A Manual for Diagnosis and Treatment . Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- PGE1 Reagent . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "PGE1 Reagent . Haemoview Diagnostics . retrieved 17 February 2016." PGE1 Reagent. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "PGE1 Reagent . Haemoview Diagnostics . retrieved 17 February 2016." PGE1 Reagent. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA PGE1 Reagent. (2026). PGE1 Reagent . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- Marcucci, Carlo. Perioperative Hemostasis: Coagulation for Anesthesiologists . · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "Marcucci, Carlo. Perioperative Hemostasis: Coagulation for Anesthesiologists ." Marcucci, Carlo. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "Marcucci, Carlo. Perioperative Hemostasis: Coagulation for Anesthesiologists ." Marcucci, Carlo. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA Marcucci, Carlo. (2026). Marcucci, Carlo. Perioperative Hemostasis: Coagulation for Anesthesiologists . Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- ADPtest . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "ADPtest . Haemoview Diagnostics . retrieved 17 February 2016." ADPtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "ADPtest . Haemoview Diagnostics . retrieved 17 February 2016." ADPtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA ADPtest. (2026). ADPtest . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- ASPItest . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "ASPItest . Haemoview Diagnostics . retrieved 17 February 2016." ASPItest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "ASPItest . Haemoview Diagnostics . retrieved 17 February 2016." ASPItest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA ASPItest. (2026). ASPItest . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- COLtest . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "COLtest . Haemoview Diagnostics . retrieved 17 February 2016." COLtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "COLtest . Haemoview Diagnostics . retrieved 17 February 2016." COLtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA COLtest. (2026). COLtest . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- RISTOtest . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "RISTOtest . Haemoview Diagnostics . retrieved 17 February 2016." RISTOtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "RISTOtest . Haemoview Diagnostics . retrieved 17 February 2016." RISTOtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA RISTOtest. (2026). RISTOtest . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- TRAPtest . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "TRAPtest . Haemoview Diagnostics . retrieved 17 February 2016." TRAPtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "TRAPtest . Haemoview Diagnostics . retrieved 17 February 2016." TRAPtest. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA TRAPtest. (2026). TRAPtest . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- ASA Reagent . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "ASA Reagent . Haemoview Diagnostics . retrieved 17 February 2016." ASA Reagent. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "ASA Reagent . Haemoview Diagnostics . retrieved 17 February 2016." ASA Reagent. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA ASA Reagent. (2026). ASA Reagent . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
- GPIIb/IIIa Antagonist Reagent . Haemoview Diagnostics . retrieved 17 February 2016 · retrieved 2026-07-17 · rev 1364801272
Cite this reference
MLA "GPIIb/IIIa Antagonist Reagent . Haemoview Diagnostics . retrieved 17 February 2016." GPIIb/IIIa Antagonist Reagent. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272. Accessed 28 November 2026.
Chicago "GPIIb/IIIa Antagonist Reagent . Haemoview Diagnostics . retrieved 17 February 2016." GPIIb/IIIa Antagonist Reagent. 2026-07-17. https://en.wikipedia.org/w/index.php?oldid=1364801272.
APA GPIIb/IIIa Antagonist Reagent. (2026). GPIIb/IIIa Antagonist Reagent . Haemoview Diagnostics . retrieved 17 February 2016. Retrieved November 28, 2026, from https://en.wikipedia.org/w/index.php?oldid=1364801272
Cite this article
MLA
"Multiple electrode aggregometry." encyclopegia.org, 2026, https://encyclopegia.org/wiki/multiple-electrode-aggregometry. Accessed 28 November 2026.
Chicago
"Multiple electrode aggregometry." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/multiple-electrode-aggregometry.
APA
encyclopegia.org. (2026). Multiple electrode aggregometry. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/multiple-electrode-aggregometry
Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON