Open wire
Open wire was an early transmission technology in telecommunication, first used in telegraphy.[src] It consisted of pairs of electric wire strung on a pole line between communities, towns, and cities.[src] for long-distance transmission line The wire of the transmission line was attached to the cross-arms of each pole with glass insulators.[src] It was originally manufactured from iron or steel, but developments in annealing of copper made it possible to use this metal by the 1890s to reduce electrical resistance substantially.[src] Copper wire was drawn to a diameter of up to 1/6 inch (165 mils).[src] The glass insulators on the pole cross-arms were spaced at about 12 inches (30cm) apart.[src] Typically up to five wire pairs were installed on each crossarm, and multiple cross-arms could be installed on each pole.[src] The practical limit in distance of telephone communication via open-wire transmission was reached when the Bell System long-distance network was extended from New York City to Denver in 1911.[src] Despite heavy-gauge wire, and using loading coils to reduce transmission loss, talking was just barely possible over the line until the first Audion amplifiers were added.[src] Open wire systems along power lines use differential transformers for common-mode signal suppression at both ends.[src] In many countries like Germany, open wire systems are not used any more for the public telephone grid.…[src]
Open wire was an early transmission technology in telecommunication, first used in telegraphy.[src] It consisted of pairs of electric wire strung on a pole line between communities, towns, and cities.[src] for long-distance transmission line The wire of the transmission line was attached to the cross-arms of each pole with glass insulators.[src] It was originally manufactured from iron or steel, but developments in annealing of copper made it possible to use this metal by the 1890s to reduce electrical resistance substantially.[src] Copper wire was drawn to a diameter of up to 1/6 inch (165 mils).[src] The glass insulators on the pole cross-arms were spaced at about 12 inches (30cm) apart.[src] Typically up to five wire pairs were installed on each crossarm, and multiple cross-arms could be installed on each pole.[src] The practical limit in distance of telephone communication via open-wire transmission was reached when the Bell System long-distance network was extended from New York City to Denver in 1911.[src] Despite heavy-gauge wire, and using loading coils to reduce transmission loss, talking was just barely possible over the line until the first Audion amplifiers were added.[src] Open wire systems along power lines use differential transformers for common-mode signal suppression at both ends.[src] In many countries like Germany, open wire systems are not used any more for the public telephone grid.[src] However, such installations are still operated along non-electrified railway lines, for internal communication of the railway operator.[src] ==See also== General Toll Switching Plan Overhead power line ==References== Chapman, A.G.[src] Open-Wire Crosstalk, BSTJ 13(1)19, January 1934 B.C.[src] Griffith, H.[src] Kahl, Type-O Carrier System Objectives BLR 32(6)p209 (June 1954)[src]
27 sentences · 27 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Open wire." encyclopegia.org, 2026, https://encyclopegia.org/wiki/open-wire. Accessed 25 November 2026.
Chicago
"Open wire." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/open-wire.
APA
encyclopegia.org. (2026). Open wire. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/open-wire
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON