power factor
In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of root mean square (RMS) current and voltage. Apparent power is often higher than real power because energy is cyclically accumulated in the load and returned to the source or because a non-linear load distorts the wave shape of the current. Where apparent power exceeds real power, more current is flowing in the circuit than would be required to transfer real power. Where the power factor magnitude is less than one, the voltage and current are not in phase, which reduces the average product of the two. A negative power factor occurs when the device (normally the load) generates real power, which then flows back towards the source. In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The larger currents increase the energy lost in the distribution system and require larger wires and other equipment.…
In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of root mean square (RMS) current and voltage. Apparent power is often higher than real power because energy is cyclically accumulated in the load and returned to the source or because a non-linear load distorts the wave shape of the current. Where apparent power exceeds real power, more current is flowing in the circuit than would be required to transfer real power. Where the power factor magnitude is less than one, the voltage and current are not in phase, which reduces the average product of the two. A negative power factor occurs when the device (normally the load) generates real power, which then flows back towards the source. In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The larger currents increase the energy lost in the distribution system and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers with a low power factor. Power-factor correction (PFC) increases the power factor of a load, improving efficiency for the distribution system to which it is attached. Linear loads with a low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment. ==General case== The general expression for power factor is given by \mbox{power factor} = P/P_a P_a = I_{rms} V_{rms} where P is the real power measured by an ideal wattmeter, I_{rms} is the rms current measured by an ideal ammeter, and V_{rms} is the rms voltage measured by an ideal voltmeter. Apparent power, P_a , is the product of the rms current and the rms voltage. If the load is sourcing power back toward the generator, then P and \mbox{power factor} will be negative. If the waveforms are periodic with the same fundamental period, then the power factor can be computed as follows: \begin{align} P &=\frac{1}{T} \int_{t'}^{t'+T} i(t)v(t) dt,\\ I_{rms} &=\sqrt{\frac{1}{T} \int_{t'}^{t'+T} {i(t)}^2 dt},\\ V_{rms} &=\sqrt{\frac{1}{T} \int_{t'}^{t'+T} {v(t)}^2 dt},\\ \mbox{power factor} &= \frac{P}{I_{rms}V_{rms}}, \end{align} where i(t) is the instantaneous current, v(t) is the instantaneous voltage, t' is an arbitrary starting time, and T is the period of the waveforms. If the waveforms are not periodic and the physical meters have the same averaging time, then the equations for the periodic case can be used with the exception that T is the averaging time of the meters instead of the waveform period. S &= P + jQ \\ |S| &= \sqrt{P^2 + Q^2} \\ \text{pf} &= \cos{\theta} = \frac{P} = \cos{ \left( \arctan{ \left( \frac{Q}{P} \right) } \right) } \\ Q &= P \, \tan(\arccos(\text{pf})) \end{align} As the angle θ increases with fixed total apparent power, current and voltage are further out of phase with each other. Real power decreases, and reactive power increases. |P| = |S| \cos\theta Since the units are consistent, the power factor is by definition a dimensionless number between -1 and 1. When the power factor is equal to 0, the energy flow is entirely reactive, and stored energy in the load returns to the source on each cycle. When the power factor is 1, referred to as the unity power factor, all the energy supplied by the source is consumed by the load. Power factors are usually stated as leading or lagging to show the sign of the phase angle. Capacitive loads are leading (current leads voltage), and inductive loads are lagging (current lags voltage). If a purely resistive load is connected to a power supply, current and voltage will change polarity in step, the power factor will be 1, and the electrical energy flows in a single direction across the network in each cycle. Inductive loads such as induction motors (any type of wound coil) consume reactive power with the current waveform lagging the voltage. Capacitive loads such as capacitor banks or buried cables generate reactive power with the current phase leading the voltage. Both types of loads will absorb energy during part of the AC cycle, which is stored in the device's magnetic or electric field, only to return this energy back to the source during the rest of the cycle. For example, to get 1 kW of real power, if the power factor is unity, 1 kVA of apparent power needs to be transferred (1 kW ÷ 1 = 1 kVA). At low values of power factor, more apparent power needs to be transferred to get the same real power. To get 1 kW of real power at 0.2 power factor, 5 kVA of apparent power needs to be transferred (1 kW ÷ 0.2 = 5 kVA). This apparent power must be produced and transmitted to the load and is subject to losses in the production and transmission processes. Electrical loads consuming alternating current power consume both real power and reactive power. The vector sum of real and reactive power is the complex power, and its magnitude is the apparent power. The presence of reactive power causes the real power to be less than the apparent power, and so, the electric load has a power factor of less than 1. A negative power factor (0 to −1) can result from returning active power to the source, such as in the case of a building fitted with solar panels when surplus power is fed back into the supply. & = \frac{ I_1}{I_{rms}} \\ & = \frac{I_1} {\sqrt{I_1^2+I_2^2+I_3^2+I_4^2+\cdots}} \\ & = \frac{1} { \sqrt{1+ \frac{I_2^2+I_3^2+I_4^2+\cdots}{I_1^2}}} \\ & = \frac{1} {\sqrt{ 1+THD_i^2}} \\ \end{align} \mbox{THD}_i is the total harmonic distortion of the load current. THD_i = \frac{\sqrt{\displaystyle\sum_{h=2}^\infty I_h^2}} {I_1}= \frac{\sqrt{I_2^2+I_3^2+I_4^2+\cdots}} {I_1} I_1 is the fundamental component of the current, I_{rms} is the total current, and I_h is the current on the h th harmonic; all are root mean square values (distortion power factor can also be used to describe individual order harmonics, using the corresponding current in place of total current). This definition with respect to total harmonic distortion assumes that the voltage stays undistorted (sinusoidal, without harmonics). This simplification is often a good approximation for stiff voltage sources (not being affected by changes in load downstream in the distribution network). Total harmonic distortion of typical generators from current distortion in the network is on the order of 1–2%, which can have larger scale implications but can be ignored in common practice. The result when multiplied with the displacement power factor is the overall, true power factor or just power factor (PF): \mbox{PF} = \frac{\cos{\varphi}} {\sqrt{ 1+THD_i^2}}
References
No reference rows published for this article.
Cite this article
MLA
"power factor." encyclopegia.org, 2026, https://encyclopegia.org/wiki/power-factor. Accessed 25 November 2026.
Chicago
"power factor." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/power-factor.
APA
encyclopegia.org. (2026). power factor. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/power-factor
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON