Power usage effectiveness (PUE) or power unit efficiency is a ratio that describes how efficiently a computer data center uses energy; specifically, how much energy is used by the computing equipment (in contrast to cooling and other overhead that supports the equipment).[src] PUE is the ratio of the total amount of energy used by a computer data center facility to the energy delivered to computing equipment.[src] PUE is the inverse of data center infrastructure efficiency.[src] PUE was originally developed by a consortium called The Green Grid.[src] PUE was published in 2016 as a global standard under ISO/IEC 30134-2:2016 An ideal PUE is 1.0.[src] Anything that isn't considered a computing device in a data center (e.g.[src] lighting, cooling, etc.) falls into the category of facility energy consumption.[src] : \mathrm{PUE} = {\mbox{Total Facility Energy} \over \mbox{IT Equipment Energy}} = 1 + {\mbox{Non IT Facility Energy} \over \mbox{IT Equipment Energy}}[src]

Power usage effectiveness (PUE) or power unit efficiency is a ratio that describes how efficiently a computer data center uses energy; specifically, how much energy is used by the computing equipment (in contrast to cooling and other overhead that supports the equipment).[src] PUE is the ratio of the total amount of energy used by a computer data center facility to the energy delivered to computing equipment.[src] PUE is the inverse of data center infrastructure efficiency.[src] PUE was originally developed by a consortium called The Green Grid.[src] PUE was published in 2016 as a global standard under ISO/IEC 30134-2:2016 An ideal PUE is 1.0.[src] Anything that isn't considered a computing device in a data center (e.g.[src] lighting, cooling, etc.) falls into the category of facility energy consumption.[src] \mathrm{PUE} = {\mbox{Total Facility Energy} \over \mbox{IT Equipment Energy}} = 1 + {\mbox{Non IT Facility Energy} \over \mbox{IT Equipment Energy}} ==Benefits and limitation== PUE was introduced in 2006 and promoted by The Green Grid (a non-profit organization of IT professionals) in 2007, and has become the most commonly used metric for reporting the energy efficiency of data centres.[src] Although it is named "power usage effectiveness", it actually measures the energy use of the data centre.[src] The PUE metric has several benefits: calculation can be repeated over time, allowing a company to view their efficiency changes historically, or during time-limited events like seasonal changes companies can gauge how more efficient practices (such as powering down idle hardware) affect their overall usage the PUE metric creates competition, “driving efficiencies up as advertised PUE values become lower".[src] Companies can then use PUE as a marketing tool.[src] However, there are some issues with the PUE metric.[src] The main one arises from the way the ratio is calculated.[src] Because IT load is the sole denominator, any reduction in IT load (for example through virtualisation allowing some hardware to be stood down, or simply through more energy-efficient hardware) will cause the PUE to rise paradoxically.[src] Some other issues are the efficiency of the power supply network and calculating the accurate IT load.[src] According to the sensitivity analysis by Brady et al., "Total energy consumption is equal to the total amount of energy used by the equipment and infrastructure in the facility (WT) plus the energy losses due to inefficiencies in the power delivery network (WL), hence: PUE=(WT+WL)/WIT." Based on the equation, the inefficiencies of the power delivery network (WL) will increase the total energy consumption of the data center.[src] The PUE value goes up as the data center becomes less efficient.[src] IT load is another important issue of the PUE metric.[src] "It is crucial that an accurate IT load is used for the PUE, and that it is not based upon the rated power use of the equipment.[src] Accuracy in the IT load is one of the major factors affecting the measurement of the PUE metric, as utilization of the servers has an important effect on IT energy consumption and hence the overall PUE value".[src] For example, a data center with high PUE value and high server utilization could be more efficient than a data center with low PUE value and low server utilization.[src] There is also some concern within the industry of PUE as a marketing tool leading some to use the term "PUE Abuse".[src] Power Compute Effectiveness (PCE) has been proposed in research and industry discussions as a complementary metric to Power Usage Effectiveness.[src] While PUE evaluates the ratio of total facility energy to IT equipment energy, PCE is the ratio of provisioned IT compute power allocation to total provisioned site electrical capacity.[src] Studies and standards‑development groups have examined PCE as part of a broader shift toward compute‑centric efficiency metrics, particularly for environments where workload output provides a more meaningful indicator of system‑level efficiency than infrastructure overhead.[src] ==Notably efficient companies== In October 2008, Google's data center was noted to have a ratio of 1.21 PUE across all 6 of its centers, which at the time was considered as close to perfect as possible.[src] Right behind Google was Microsoft, which had another notable PUE ratio of 1.22.[src] Since 2015, Switch, the developer of SUPERNAP data centers, has had a third party audited colocation PUE of 1.18 for its SUPERNAP 7 Las Vegas, Nevada facility, with an average cold aisle temp of and average humidity of 40.3%.[src] This is attributed to Switch's patented hot aisle containment and HVAC technologies.[src] As of the end of Q2 2015, Facebook's Prineville data center had a power usage effectiveness (PUE) of 1.078 and its Forest City data center had a PUE of 1.082.[src] In October 2015, Allied Control has a claimed PUE ratio of 1.02 through the use of two-phase immersion cooling using 3M Novec 7100 fluid.[src] In January 2016, the Green IT Cube in Darmstadt was dedicated with a 1.07 PUE.[src] It uses cold water cooling through the rack doors.[src] In February 2017, Supermicro has announced deployment of its disaggregated MicroBlade systems.[src] An unnamed Fortune 100 company has deployed over 30,000 Supermicro MicroBlade servers at its Silicon Valley data center with a (PUE) of 1.06.[src] Through proprietary innovations in liquid cooling systems, French hosting company OVH has managed to attain a PUE ratio of 1.09 in its data centers in Europe and North America while in 2023 they reported a 12 months overall PUE of 1.29.[src] In 2021, Google reported a PUE of 1.1 across their data centers worldwide, and less than 1.06 for their best sites.[src] In scientific projects in 2022, the Research Institutes of Sweden reported a PUE of 1.0148, notably reached in the north of Sweden.[src] ==References==[src]

47 sentences · 47 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Power usage effectiveness." encyclopegia.org, 2026, https://encyclopegia.org/wiki/power-usage-effectiveness. Accessed 28 November 2026.

Chicago

"Power usage effectiveness." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/power-usage-effectiveness.

APA

encyclopegia.org. (2026). Power usage effectiveness. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/power-usage-effectiveness

Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON

Claims

PredicateValueSource
publication date2016Wikipedia
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1367073325 · 0.5 · snapshot enwiki-001367073325

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.