Pre-charge of the powerline voltages in a high voltage DC application is a preliminary mode which limits the inrush current during the power up procedure.[src] A high-voltage system with a large capacitive load can be exposed to high electric current during initial turn-on.[src] This current, if not limited, can cause considerable stress or damage to the system components.[src] In some applications, the occasion to activate the system is a rare occurrence, such as in commercial utility power distribution.[src] In other systems such as vehicle applications, pre-charge will occur with each use of the system, multiple times per day.[src] Precharging is implemented to increase the lifespan of electronic components and increase reliability of the high voltage system.[src]

Pre-charge of the powerline voltages in a high voltage DC application is a preliminary mode which limits the inrush current during the power up procedure.[src] A high-voltage system with a large capacitive load can be exposed to high electric current during initial turn-on.[src] This current, if not limited, can cause considerable stress or damage to the system components.[src] In some applications, the occasion to activate the system is a rare occurrence, such as in commercial utility power distribution.[src] In other systems such as vehicle applications, pre-charge will occur with each use of the system, multiple times per day.[src] Precharging is implemented to increase the lifespan of electronic components and increase reliability of the high voltage system.[src] The current into a capacitor is known to be I = C(dV/dT) : the peak inrush current will depend upon the capacitance C and the rate of change of the voltage (dV/dT).[src] The inrush current will increase as the capacitance value increases, and the inrush current will increase as the voltage of the power source increases.[src] This second parameter is of primary concern in high voltage power distribution systems.[src] By their nature, high voltage power sources will deliver high voltage into the distribution system.[src] Capacitive loads will then be subject to high inrush currents upon power-up.[src] The stress to the components must be understood and minimized.[src] The objective of a pre-charge function is to limit the magnitude of the inrush current into capacitive loads during power-up.[src] This may take several seconds depending on the system.[src] In general, higher voltage systems benefit from longer pre-charge times during power-up.[src] Consider an example where a high voltage source powers up a typical electronics control unit which has an internal power supply with 11000 μF input capacitance.[src] When powered from a 28 V source, the inrush current into the electronics unit would approach 31 amperes in 10 milliseconds.[src] If that same circuit is activated by a 610 V source, then the inrush current would approach 670 A in 10 milliseconds.[src] It is wise not to allow unlimited inrush currents from high voltage power distribution system activation into capacitive loads: instead the inrush current should be controlled to avoid power-up stress to components.[src]

25 sentences · 25 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Pre-charge." encyclopegia.org, 2026, https://encyclopegia.org/wiki/pre-charge. Accessed 29 November 2026.

Chicago

"Pre-charge." encyclopegia.org. Accessed November 29, 2026. https://encyclopegia.org/wiki/pre-charge.

APA

encyclopegia.org. (2026). Pre-charge. Retrieved November 29, 2026, from https://encyclopegia.org/wiki/pre-charge

Accessed November 29, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Pré-Saint-Didier

stub · references available

Pre-Islamic Arabia

stub · references available

chargé d'affaires

stub · references available

charge-parity-time symmetry

stub · references available

PRE-084

stub · references available

Pre-Columbian studies

stub · references available

Pre

stub · references available
CC BY-SA 4.0 · tier1-factual · https://en.wikipedia.org/w/index.php?oldid=1354921569 · 0.55 · snapshot pre-charge-815910-fc17bba5e30ddf69 · QID Q7239201

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners
  • Index — every corpus, paper and record
  • Estate guide — what a public data estate is
  • Founder — Lois-Kleinner Alpasan
  • Records — DOIs and external deposits
  • Documents — one-pagers, PDFs and QR codes
  • Brand kit — logos and share images
  • Papers — plain-language briefs with citations
  • Browser — search engine, PWA and bookmarklet
  • Anticloud — the operator and its projects

As seen in Business Insider · 336 outlets · evidence DOIs · plain-language papers

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.