Push–pull perfusion
Push–pull perfusion is an in vivo sampling method most commonly used for measuring neurotransmitters in the brain.[src] Developed by J.H.[src] Gaddum in 1960, this technique replaced the cortical cup technique for observing neurotransmitters.[src] In order to analyze concentrations of analytes such as neurotransmitters, a probe consisting of two concentric tubes is implanted in the region of interest.[src] A pump then pushes a neutral fluid such as saline or Ringer's solution through one of the tubes, while another pump extracts the fluid through the other tube.[src] While outside the tubes, the perfusion fluid picks up physiological substances such as neurotransmitters that are present in the area.[src] The concentration of analytes of interest can then be measured in the expelled fluid, indicating in which concentration they are present at the site of interest at any given time.[src] The advent of concentric microdialysis probes in the 1980s resulted in push-pull sampling falling out of favor, as such probes require less monitoring, and are less invasive than the higher flow rate push-pull probes (>10 microliter/min), which could result in lesions if flow is unbalanced.[src] With the advent of microfluidics and miniaturized probes, low-flow push–pull sampling was developed in 2002.…[src]
Push–pull perfusion is an in vivo sampling method most commonly used for measuring neurotransmitters in the brain.[src] Developed by J.H.[src] Gaddum in 1960, this technique replaced the cortical cup technique for observing neurotransmitters.[src] In order to analyze concentrations of analytes such as neurotransmitters, a probe consisting of two concentric tubes is implanted in the region of interest.[src] A pump then pushes a neutral fluid such as saline or Ringer's solution through one of the tubes, while another pump extracts the fluid through the other tube.[src] While outside the tubes, the perfusion fluid picks up physiological substances such as neurotransmitters that are present in the area.[src] The concentration of analytes of interest can then be measured in the expelled fluid, indicating in which concentration they are present at the site of interest at any given time.[src] The advent of concentric microdialysis probes in the 1980s resulted in push-pull sampling falling out of favor, as such probes require less monitoring, and are less invasive than the higher flow rate push-pull probes (>10 microliter/min), which could result in lesions if flow is unbalanced.[src] With the advent of microfluidics and miniaturized probes, low-flow push–pull sampling was developed in 2002.[src] By using flow rates of ~50 nL/min, this technique minimizes tissue damage while providing finer spatial resolution than microdialysis sampling.[src]
19 sentences · 19 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Push–pull perfusion." encyclopegia.org, 2026, https://encyclopegia.org/wiki/push-pull-perfusion. Accessed 27 November 2026.
Chicago
"Push–pull perfusion." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/push-pull-perfusion.
APA
encyclopegia.org. (2026). Push–pull perfusion. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/push-pull-perfusion
Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON