Q meter
A Q meter is a piece of equipment used in the testing of radio frequency circuits.[src] It has been largely replaced in professional laboratories by other types of impedance measuring devices, though it is still in use among radio amateurs.[src] It was developed at Boonton Radio Corporation in Boonton, New Jersey in 1934 by William D.[src] Loughlin.[src]
A Q meter is a piece of equipment used in the testing of radio frequency circuits.[src] It has been largely replaced in professional laboratories by other types of impedance measuring devices, though it is still in use among radio amateurs.[src] It was developed at Boonton Radio Corporation in Boonton, New Jersey in 1934 by William D.[src] Loughlin.[src] ==Description== A Q meter measures the quality factor of a circuit, Q, which expresses how much energy is dissipated per cycle in a non-ideal reactive circuit: Q = 2 \pi \times \frac{\mbox{Peak Energy Stored}}{\mbox{Energy dissipated per cycle}}.[src] \, This expression applies to an RF and microwave filter, bandpass LC filter, or any resonator.[src] It also can be applied to an inductor or capacitor at a chosen frequency.[src] For inductors Q = \frac{X_L}{R} = \frac{\omega L}{R} Where X_L is the reactance of the inductor, L is the inductance, \omega is the angular frequency and R is the resistance of the inductor.[src] The resistance R represents the loss in the inductor, mainly due to the resistance of the wire.[src] A Q meter works on the principle of series resonance.[src] For LC band pass circuits and filters: Q = \frac{F}{BW} Where F is the resonant frequency (center frequency) and BW is the filter bandwidth.[src] In a band pass filter using an LC resonant circuit, when the loss (resistance) of the inductor increases, its Q factor is reduced, and so the bandwidth of the filter is increased.[src] In a coaxial cavity filter, there are no inductors and capacitors, but the cavity has an equivalent LC model with losses (resistance) and the Q factor can be applied as well.[src] ==Operation== Internally, a minimal Q meter consists of a tuneable RF generator with a very low (pass) impedance output and a detector with a very high impedance input.[src] There is usually provision to add a calibrated amount of high Q capacitance across the component under test to allow inductors to be measured in isolation.[src] The generator is effectively placed in series with the tuned circuit formed by the components under test, and having negligible output resistance, does not materially affect the Q factor, while the detector measures the voltage developed across one element (usually the capacitor) and being high impedance in shunt does not affect the Q factor significantly either.[src] The ratio of the developed RF voltage to the applied RF current, coupled with knowledge of the reactive impedance from the resonant frequency, and the source impedance, allows the Q factor to be directly read by scaling the detected voltage.[src] ==See also== LCR meter ESR meter ==References== ==Further reading== "An experimental 'Q' meter" — article by Lloyd Butler (originally published in Amateur Radio, November 1988; revised April 2004)[src]
22 sentences · 22 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Q meter." encyclopegia.org, 2025, https://encyclopegia.org/wiki/q-meter. Accessed 29 November 2026.
Chicago
"Q meter." encyclopegia.org. Accessed November 29, 2026. https://encyclopegia.org/wiki/q-meter.
APA
encyclopegia.org. (2025). Q meter. Retrieved November 29, 2026, from https://encyclopegia.org/wiki/q-meter
Accessed November 29, 2026 · CC BY-SA 4.0 · citation page · JSON
Claims
| Predicate | Value | Source |
|---|---|---|
| publication date | 1988 | Wikipedia |