RadBall
The RadBall is a diameter deployable, passive, non-electrical gamma hot-spot imaging device that offers a 360 degree view of the deployment area.[src] The device is particularly useful in instances where the radiation fields inside a nuclear facility are unknown but required in order to plan a suitable nuclear decommissioning strategy.[src] The device has been developed by the UK's National Nuclear Laboratory and consists of an inner spherical core made of a radiation sensitive material and an outer tungsten based collimation sheath.[src] The device does not require any electrical supply or communication link and can be deployed remotely thus eliminating the need for radiation exposure to personnel.[src] In addition to this, the device has a very wide target dose range of between 2 and 5,000 rads (20 mGy to 50 Gy) which makes the technology widely applicable to nuclear decommissioning applications.[src]
The RadBall is a diameter deployable, passive, non-electrical gamma hot-spot imaging device that offers a 360 degree view of the deployment area.[src] The device is particularly useful in instances where the radiation fields inside a nuclear facility are unknown but required in order to plan a suitable nuclear decommissioning strategy.[src] The device has been developed by the UK's National Nuclear Laboratory and consists of an inner spherical core made of a radiation sensitive material and an outer tungsten based collimation sheath.[src] The device does not require any electrical supply or communication link and can be deployed remotely thus eliminating the need for radiation exposure to personnel.[src] In addition to this, the device has a very wide target dose range of between 2 and 5,000 rads (20 mGy to 50 Gy) which makes the technology widely applicable to nuclear decommissioning applications.[src] ==The device== The device consists of two constituent parts, a gamma radiation sensitive inner core which fits inside the spherical tungsten outer collimation sheath.[src] The outside diameter of the device is 140 mm (approx 5 ½ inch) which allows deployment in to hard to reach areas whilst providing a 360 degree view of the area.[src] The inner core is made up of material which changes colour when it is exposed to gamma radiation.[src] Therefore, when the device is deployed inside a radioactive environment the collimation device preferentially allows gamma radiation to pass through the collimation holes which deposits tracks within the inner core.[src] These tracks can then be analysed to provide a 3D visualisation of the radioactive environment predicting both source location and intensity.[src] ==Deployment and retrieval== The overall radiation mapping service based on the device consists of six individual steps.[src] Step 1 involves placing the device inside the given contaminated area with a known position and orientation.[src] This can be achieved in a number of ways including deployment by crane, robot, by an operator or (as in most cases) by a remotely operated manipulator arm.[src] The device can be orientated either upright or upside down.[src] Once the device has been placed in position, Step 2 involves leaving the device in-situ to enable dose uptake.[src] Once the device has been left in-situ and has achieved a suitable dose uptake (between 2 and 5,000 rads), Step 3 involves removing the device from the contaminated area.[src] Once clearance has been given, Step 4 involves removing the radiation sensitive core from within the collimation device, ensuring that it has not rotated or moved during the deployment period.[src] ==Analysis and visualisation== Step 5 involves scanning the radiation sensitive core using an optical technique which digitises the information captured by the inner core.[src] Step 6 involves the interpretation of this data set to produce a final visualisation.[src] For each detected track within the inner core special software creates a line of best fit for the data points provided and chooses the direction of the track by using the intensity values.[src] This line of best fit is extrapolated until it intersects with a wall of the deployment volume.[src] This indicates that the radiation source is on the wall at this location or anywhere along the line of sight between the device and the point on the wall.[src] If two devices are deployed in different locations within the same deployment area, triangulation can be used to predict where along the extrapolated line the radiation source is.[src] ==Benefits over existing technology== A number of alternative technologies and approaches do exist ranging from the use of GM based detectors mounted on a manipulator and moved around a radioactive cell to heavily shielded and collimated gamma-based camera.[src] The technology tested here does have a number of advantages over the aforementioned.[src] With regard to the GM / manipulator approach, the technology has directional awareness, an ability to distinguish separate sources which are in close proximity, there is no need for a power or data umbilical and the technology can be used in areas where a manipulator is not present.[src] With regard to the heavily collimated gamma camera technology, the technology also has a number of advantages including a much more compact size, less weight, no power and data umbilical as well as offering a lower financial risk should the equipment become contaminated.[src] ==Deployment history== The technology has been successfully deployed a number of times throughout the US and the UK as described below.[src] ===Savannah River Site, USA=== The earliest lab based tests undertaken on the original version of the technology was performed at the Savannah River Site (SRS) Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics.[src] The objective of these preliminary tests was to identify the optimal target dose and collimator thickness of the device.[src] The second set of tests involved the deployment of device in a contaminated Hot Cell in order to characterise the radiation sources within.[src] This work is described in a number of previous publications, primarily in a report commissioned by the US Department of Energy, but also in a number of journal publications.[src] and general industrial news outlets.[src] ===Hanford Site, USA=== Further testing of the original device was undertaken in order to demonstrate that the technology could locate submerged radiological hazards.[src] This study involved, for the first time, underwater deployments at the US Department of Energy Hanford Site.[src] This study represents the first successful underwater deployment of technology and a further step in demonstrating that the technology has the ability to be remotely deployed with no electrical supplies into difficult to access areas and locate radiation hazards.[src] This study was part of ongoing work to investigate whether the technology is able to characterize more complex radiation environments as described previously.[src] ===Oak Ridge National Laboratory, USA=== A number of trials took place at the US Department of Energy Oak Ridge National Laboratory (ORNL) during December 2010 as described previously.[src] The overall objective for these trials was to demonstrate that a newly developed technology could be used to locate, quantify and characterise the radiological hazards within two separate Hot Cells (B and C).[src] For Hot Cell B, the primary objective of demonstrating that the technology could be used to locate, quantify and characterise 3 radiological sources has been met with 100% success.[src] Despite more challenging conditions in Hot Cell C, two sources were detected and accurately located.[src] To summarise, the technology performed extremely well with regard to detecting and locating radiation sources and, despite the challenging conditions, moderately well when assessing the relative energy and intensity of those sources.[src] ===Sellafield Site, UK=== More recently during Winter 2011 the technology was successfully deployed on the UK's Sellafield Site in order to map the whereabouts of numerous radioactive containers within a Shielded Cell Facility.[src] This particular project involved the deployment of three devices and represents the first instance in which triangulation was demonstrated.[src] Overall the technology performed well by locating and quantifying around a dozen sources.[src] This work package was undertaken in partnership with Sellafield Ltd.[src] ==References== ==External links== National Nuclear Laboratory (NNL) home page National Nuclear Laboratory Waste Management and Decommissioning home page National Nuclear Laboratory RadBall home page RadBall - Double Winner![src] Inventions aid nuclear clean-up On the ball RadBall Creates 3D Radiation Maps Radball ready to roll[src]
53 sentences · 53 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"RadBall." encyclopegia.org, 2026, https://encyclopegia.org/wiki/radball. Accessed 25 November 2026.
Chicago
"RadBall." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/radball.
APA
encyclopegia.org. (2026). RadBall. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/radball
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON