encyclopegia.org

Rivalta test

Certain diseases can cause excessive accumulations of fluid in areas of the body such as the abdomen (ascites) or the pleural space around the lungs (pleural effusion) or the pericardial space around the heart.[src] An estimate of the concentration of protein in such fluids can narrow the differential diagnosis and assist the clinician in establishing a diagnosis.[src] For example, fluid accumulations due to congestive heart failure and liver failure (cirrhosis) are typically lower in protein content and are called transudates whereas fluid accumulations due to cancer and tuberculosis are typically higher in protein content and are called exudates.[src] The Rivalta Test is a simple, inexpensive method that can be used in resource-limited settings to differentiate a transudate from an exudate.[src] It is a simple, inexpensive method that does not require special laboratory equipment and can be easily performed in private practice.[src] The test was originally developed by the Italian researcher Rivalta around 1900 and was used to differentiate transudates and exudates in human patients.[src] It is also useful in cats to differentiate between effusions due to feline infectious peritonitis (FIP) and effusions caused by other diseases.[src] Not only the high protein content, but high concentrations of fibrinogen and inflammatory mediators lead to a positive reaction.[src]

Certain diseases can cause excessive accumulations of fluid in areas of the body such as the abdomen (ascites) or the pleural space around the lungs (pleural effusion) or the pericardial space around the heart.[src] An estimate of the concentration of protein in such fluids can narrow the differential diagnosis and assist the clinician in establishing a diagnosis.[src] For example, fluid accumulations due to congestive heart failure and liver failure (cirrhosis) are typically lower in protein content and are called transudates whereas fluid accumulations due to cancer and tuberculosis are typically higher in protein content and are called exudates.[src] The Rivalta Test is a simple, inexpensive method that can be used in resource-limited settings to differentiate a transudate from an exudate.[src] It is a simple, inexpensive method that does not require special laboratory equipment and can be easily performed in private practice.[src] The test was originally developed by the Italian researcher Rivalta around 1900 and was used to differentiate transudates and exudates in human patients.[src] It is also useful in cats to differentiate between effusions due to feline infectious peritonitis (FIP) and effusions caused by other diseases.[src] Not only the high protein content, but high concentrations of fibrinogen and inflammatory mediators lead to a positive reaction.[src] ==Method== A test tube is filled with distilled water and acetic acid is added.[src] To this mixture one drop of the effusion to be tested is added.[src] If the drop dissipates, the test is negative, indicating a transudate.[src] If the drop precipitates, the test is positive, indicating an exudate.[src] Using a pH 4.0 acetic acid solution, 8 types of proteins were identified in Rivalta reaction-positive turbid precipitates: C-reactive protein (CRP), Alpha 1-antitrypsin (alpha1-AT), Orosomucoid ((Alpha-1-acid glycoprotein or AGP)), haptoglobin (Hp), transferrin (Tf), ceruloplasmin (Cp), fibrinogen (Fg), and hemopexin (Hpx).[src] Since those are Acute-phase proteins, a positive Rivalta's test may be suggestive of inflammation.[src] ==Procedure== To perform this test, a transparent reagent tube (volume 10 ml) is filled with approximately 7–8 ml distilled water, to which 1 drop of acetic acid (8%, plain white vinegar) is added and mixed thoroughly.[src] On the surface of this solution, 1 drop of the effusion fluid is carefully layered.[src] If the drop disappears and the solution remains clear, the Rivalta's test is defined as negative.[src] If the drop retains its shape, stays attached to the surface or slowly floats down to the bottom of the tube (drop- or jelly-fish-like), the Rivalta's test is defined as positive.[src] The Rivalta's test had a high positive predictive value (86%) and a very high negative predictive value for FIP (96%) in a study in which cats that presented with effusion were investigated (prevalence of FIP 51%).[src] Positive Rivalta's test results can occur in cats with bacterial peritonitis or lymphoma.[src] ==References== http://abcd-vets.org/guidelines/feline_infectious_peritonitis/chapter-5.asp[src]

29 sentences · 29 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Rivalta test." encyclopegia.org, 2026, https://encyclopegia.org/wiki/rivalta-test. Accessed 27 November 2026.

Chicago

"Rivalta test." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/rivalta-test.

APA

encyclopegia.org. (2026). Rivalta test. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/rivalta-test

Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Izod impact strength test

stub · references available

Allen's test

stub · references available

Öko-Test

stub · references available

ABR-Test

stub · references available

Wartegg test

stub · references available

Classical test theory

stub · references available

Finkelstein's test

stub · references available

Baka and Test

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1348199451 · 0.5 · snapshot enwiki-001348199451

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.