SAIFI
The System Average Interruption Frequency Index (SAIFI) is commonly used as a reliability index by electric power utilities.[1] This index measures the average number of times that a system customer experiences an outage during the year or during a given time period.[src] SAIFI is normally calculated on either yearly or monthly basis.[src] SAIFI is calculated as: \mbox{SAIFI} = \frac{\sum{\lambda_i N_i}}{\sum{N_i}} where \lambda_i is the failure rate and N_i is the number of customers for location i .[src] In other words, \mbox{SAIFI} = \frac{\mbox{total number of customer interruptions}}{\mbox{total number of customers served}} Many factors cause power interruptions, including weather, vegetation patterns, and utility practices.[2] Utilities can report interruption duration values with major events (such as snowstorms or hurricanes), without major events, or both.[src] SAIFI is measured in units of interruptions per customer.[src] According to IEEE Standard 1366-1998 the median value for North American utilities is approximately 1.10 interruptions per customer.[src]
The System Average Interruption Frequency Index (SAIFI) is commonly used as a reliability index by electric power utilities.[1] This index measures the average number of times that a system customer experiences an outage during the year or during a given time period.[src] SAIFI is normally calculated on either yearly or monthly basis.[src] SAIFI is calculated as: \mbox{SAIFI} = \frac{\sum{\lambda_i N_i}}{\sum{N_i}} where \lambda_i is the failure rate and N_i is the number of customers for location i .[src] In other words, \mbox{SAIFI} = \frac{\mbox{total number of customer interruptions}}{\mbox{total number of customers served}} Many factors cause power interruptions, including weather, vegetation patterns, and utility practices.[2] Utilities can report interruption duration values with major events (such as snowstorms or hurricanes), without major events, or both.[src] SAIFI is measured in units of interruptions per customer.[src] According to IEEE Standard 1366-1998 the median value for North American utilities is approximately 1.10 interruptions per customer.[src] == References==[src]
17 sentences · 17 cited inline · 2 references stored
References
- Layton, Lee. Electric System Reliability Indices . www.egr.unlv.edu . 2004. · retrieved 2025-02-08 · rev 1274802650
Cite this reference
MLA "Layton, Lee. Electric System Reliability Indices . www.egr.unlv.edu . 2004." Layton, Lee. 2025-02-08. https://en.wikipedia.org/w/index.php?oldid=1274802650. Accessed 26 November 2026.
Chicago "Layton, Lee. Electric System Reliability Indices . www.egr.unlv.edu . 2004." Layton, Lee. 2025-02-08. https://en.wikipedia.org/w/index.php?oldid=1274802650.
APA Layton, Lee. (2025). Layton, Lee. Electric System Reliability Indices . www.egr.unlv.edu . 2004. Retrieved November 26, 2026, from https://en.wikipedia.org/w/index.php?oldid=1274802650
- U.S. Power Customers Experienced an Average of Nearly Five Hours of Interruptions in 2019 . · retrieved 2025-02-08 · rev 1274802650
Cite this reference
MLA "U.S. Power Customers Experienced an Average of Nearly Five Hours of Interruptions in 2019 ." U. 2025-02-08. https://en.wikipedia.org/w/index.php?oldid=1274802650. Accessed 26 November 2026.
Chicago "U.S. Power Customers Experienced an Average of Nearly Five Hours of Interruptions in 2019 ." U. 2025-02-08. https://en.wikipedia.org/w/index.php?oldid=1274802650.
APA U. (2025). U.S. Power Customers Experienced an Average of Nearly Five Hours of Interruptions in 2019 . Retrieved November 26, 2026, from https://en.wikipedia.org/w/index.php?oldid=1274802650
Cite this article
MLA
"SAIFI." encyclopegia.org, 2025, https://encyclopegia.org/wiki/saifi. Accessed 26 November 2026.
Chicago
"SAIFI." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/saifi.
APA
encyclopegia.org. (2025). SAIFI. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/saifi
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON