Sanger sequencing
Sanger sequencing is a method of DNA sequencing that involves electrophoresis and is based on the random incorporation of chain-terminating dideoxynucleotides by DNA polymerase during in vitro DNA replication.[src] After first being developed by Frederick Sanger and colleagues in 1977, it became the most widely used sequencing method for approximately 40 years.[src] An automated instrument using slab gel electrophoresis and fluorescent labels was first commercialized by Applied Biosystems in March 1987.[src] Later, automated slab gels were replaced with automated capillary array electrophoresis.[src] Recently, higher volume Sanger sequencing has been replaced by next generation sequencing methods, especially for large-scale, automated genome analyses.[src] However, the Sanger method remains in wide use for smaller-scale projects and for validation of deep sequencing results.[src] It still has the advantage over short-read sequencing technologies (like Illumina) in that it can produce DNA sequence reads of > 500 nucleotides and maintains a very low error rate with accuracies around 99.99%.[src] Sanger sequencing is still actively being used in efforts for public health initiatives such as sequencing the spike protein from SARS-CoV-2 as well as for the surveillance of norovirus outbreaks through the United States Center for Disease Control and Prevention (CDC)'s CaliciNet surveillance network.[src]
Sanger sequencing is a method of DNA sequencing that involves electrophoresis and is based on the random incorporation of chain-terminating dideoxynucleotides by DNA polymerase during in vitro DNA replication.[src] After first being developed by Frederick Sanger and colleagues in 1977, it became the most widely used sequencing method for approximately 40 years.[src] An automated instrument using slab gel electrophoresis and fluorescent labels was first commercialized by Applied Biosystems in March 1987.[src] Later, automated slab gels were replaced with automated capillary array electrophoresis.[src] Recently, higher volume Sanger sequencing has been replaced by next generation sequencing methods, especially for large-scale, automated genome analyses.[src] However, the Sanger method remains in wide use for smaller-scale projects and for validation of deep sequencing results.[src] It still has the advantage over short-read sequencing technologies (like Illumina) in that it can produce DNA sequence reads of > 500 nucleotides and maintains a very low error rate with accuracies around 99.99%.[src] Sanger sequencing is still actively being used in efforts for public health initiatives such as sequencing the spike protein from SARS-CoV-2 as well as for the surveillance of norovirus outbreaks through the United States Center for Disease Control and Prevention (CDC)'s CaliciNet surveillance network.[src] ==Method== The classical chain-termination method requires a single-stranded DNA template, a DNA primer, a DNA polymerase, normal deoxynucleotide triphosphates (dNTPs), and modified di-deoxynucleotide triphosphates (ddNTPs), the latter of which terminate DNA strand elongation.[src] These chain-terminating nucleotides lack a 3'-OH group required for the formation of a phosphodiester bond between two nucleotides, causing DNA polymerase to cease extension of DNA when a modified ddNTP is incorporated.[src] The ddNTPs may be radioactively or fluorescently labelled for detection in automated sequencing machines.[src] The DNA sample is multiplied into four separate sequencing reactions, containing all four of the standard deoxynucleotides (dATP, dGTP, dCTP and dTTP) and the DNA polymerase.[src] To each reaction is added only one of the four dideoxynucleotides (ddATP, ddGTP, ddCTP, or ddTTP), while the other added nucleotides are ordinary ones.[src] The deoxynucleotide concentration should be about 100-fold higher than that of the corresponding dideoxynucleotide (e.g.[src] 0.5mM dTTP : 0.005mM ddTTP) to allow enough fragments to be produced while still transcribing the complete sequence (but the concentration of ddNTP also depends on the desired length of sequence).[src] In other words, four separate reactions are needed in this process to test all four ddNTPs.[src] Following rounds of template DNA extension from the bound primer, the resulting DNA fragments are heat denatured and separated by size using gel electrophoresis.[src] In the original publication of 1977, the formation of base-paired loops of ssDNA was a cause of serious difficulty in resolving bands at some locations.[src] This is frequently performed using a denaturing polyacrylamide-urea gel with each of the four reactions run in one of four individual lanes (lanes A, T, G, C).[src] The DNA bands may then be visualized by autoradiography or UV light, and the DNA sequence can be directly read off the X-ray film or gel image.[src] In the image on the right, X-ray film was exposed to the gel, and the dark bands correspond to DNA fragments of different lengths.[src] A dark band in a lane indicates a DNA fragment that is the result of chain termination after incorporation of a dideoxynucleotide (ddATP, ddGTP, ddCTP, or ddTTP).[src] The relative positions of the different bands among the four lanes, from bottom to top, are then used to read the DNA sequence.[src] Technical variations of chain-termination sequencing include tagging with nucleotides containing radioactive phosphorus for radiolabelling, or using a primer labeled at the 5' end with a fluorescent dye.[src] Dye-primer sequencing facilitates reading in an optical system for slow and harder analysis and automation.[src] The later development by Leroy Hood and coworkers of fluorescently labeled ddNTPs and primers set the stage for automated, high-throughput DNA sequencing.[src] Chain-termination methods have greatly simplified DNA sequencing.[src] For example, chain-termination-based kits are commercially available that contain the reagents needed for sequencing, pre-aliquoted and ready to use.[src] Limitations include non-specific binding of the primer to the DNA, affecting accurate read-out of the DNA sequence, and DNA secondary structures affecting the fidelity of the sequence.[src] ==Microfluidic Sanger sequencing== Microfluidic Sanger sequencing is a lab-on-a-chip application for DNA sequencing, in which the Sanger sequencing steps (thermal cycling, sample purification, and capillary electrophoresis) are integrated on a wafer-scale chip using nanoliter-scale sample volumes.[src] This technology generates long and accurate sequence reads, while obviating many of the significant shortcomings of the conventional Sanger method (e.g.[src] high consumption of expensive reagents, reliance on expensive equipment, personnel-intensive manipulations, etc.) by integrating and automating the Sanger sequencing steps.[src] In its modern inception, high-throughput genome sequencing involves fragmenting the genome into small single-stranded pieces, followed by amplification of the fragments by polymerase chain reaction (PCR).[src] Adopting the Sanger method, each DNA fragment is irreversibly terminated with the incorporation of a fluorescently labeled dideoxy chain-terminating nucleotide, thereby producing a DNA "ladder" of fragments that each differ in length by one base and bear a base-specific fluorescent label at the terminal base.[src] Amplified base ladders are then separated by capillary array electrophoresis (CAE) with automated, in situ "finish-line" detection of the fluorescently labeled ssDNA fragments, which provides an ordered sequence of the fragments.[src] These sequence reads are then computer assembled into overlapping or contiguous sequences (termed "contigs") which resemble the full genomic sequence once fully assembled.[src] Sanger methods achieve maximum read lengths of approximately 800 bp (typically 500–600 bp with non-enriched DNA).[src] The longer read lengths in Sanger methods display significant advantages over other sequencing methods especially in terms of sequencing repetitive regions of the genome.[src] A challenge of short-read sequence data is particularly an issue in sequencing new genomes (de novo) and in sequencing highly rearranged genome segments, typically those seen of cancer genomes or in regions of chromosomes that exhibit structural variation.[src] ===Applications of microfluidic sequencing technologies=== Other useful applications of DNA sequencing include single nucleotide polymorphism (SNP) detection, single-strand conformation polymorphism (SSCP) heteroduplex analysis, and short tandem repeat (STR) analysis.[src] Resolving DNA fragments according to differences in size and/or conformation is the most critical step in studying these features of the genome.[src] ===Device design=== The sequencing chip has a four-layer construction, consisting of three 100-mm-diameter glass wafers (on which device elements are microfabricated) and a polydimethylsiloxane (PDMS) membrane.[src] Reaction chambers and capillary electrophoresis channels are etched between the top two glass wafers, which are thermally bonded.[src] Three-dimensional channel interconnections and microvalves are formed by the PDMS and bottom manifold glass wafer.[src] The device consists of three functional units, each corresponding to the Sanger sequencing steps.[src] The thermal cycling (TC) unit is a 250-nanoliter reaction chamber with integrated resistive temperature detector, microvalves, and a surface heater.[src] The movement of reagent between the top all-glass layer and the lower glass-PDMS layer occurs through 500-μm-diameter via-holes.[src] After thermal-cycling, the reaction mixture undergoes purification in the capture/purification chamber, and then is injected into the capillary electrophoresis (CE) chamber.[src] The CE unit consists of a 30-cm capillary which is folded into a compact switchback pattern via 65-μm-wide turns.[src] ===Sequencing chemistry=== Thermal cycling In the TC reaction chamber, dye-terminator sequencing reagent, template DNA, and primers are loaded into the TC chamber and thermal-cycled for 35 cycles ( at 95 °C for 12 seconds and at 60 °C for 55 seconds).[src] Purification The charged reaction mixture (containing extension fragments, template DNA, and excess sequencing reagent) is conducted through a capture/purification chamber at 30 °C via a 33-Volts/cm electric field applied between capture outlet and inlet ports.[src] The capture gel through which the sample is driven, consists of 40 μM of oligonucleotide (complementary to the primers) covalently bound to a polyacrylamide matrix.[src] Extension fragments are immobilised by the gel matrix, and excess primer, template, free nucleotides, and salts are eluted through the capture waste port.[src] The capture gel is heated to 67–75 °C to release extension fragments.[src] Capillary electrophoresis Extension fragments are injected into the CE chamber where they are electrophoresed through a 125-167-V/cm field.[src] ===Platforms=== The Apollo 100 platform (Microchip Biotechnologies Inc., Dublin, California) integrates the first two Sanger sequencing steps (thermal cycling and purification) in a fully automated system.[src] The manufacturer claims that samples are ready for capillary electrophoresis within three hours of the sample and reagents being loaded into the system.[src] The Apollo 100 platform requires sub-microliter volumes of reagents.[src] ===Comparisons to other sequencing techniques=== The ultimate goal of high-throughput sequencing is to develop systems that are low-cost, and extremely efficient at obtaining extended (longer) read lengths.[src] Longer read lengths of each single electrophoretic separation, substantially reduces the cost associated with de novo DNA sequencing and the number of templates needed to sequence DNA contigs at a given redundancy.[src] Microfluidics may allow for faster, cheaper and easier sequence assembly.[src]
69 sentences · 69 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Sanger sequencing." encyclopegia.org, 2026, https://encyclopegia.org/wiki/sanger-sequencing. Accessed 29 November 2026.
Chicago
"Sanger sequencing." encyclopegia.org. Accessed November 29, 2026. https://encyclopegia.org/wiki/sanger-sequencing.
APA
encyclopegia.org. (2026). Sanger sequencing. Retrieved November 29, 2026, from https://encyclopegia.org/wiki/sanger-sequencing
Accessed November 29, 2026 · CC BY-SA 4.0 · citation page · JSON