encyclopegia.org

Section 608

Section 608 (together with Section 609, which covers motor vehicles) of the Clean Air Act serves as the main form of occupational licensure for technicians in the heating, ventilation, and air conditioning (HVAC) industry in the United States. The law requires that all persons who maintain, service, repair or dispose of appliances that contain regulated refrigerants be certified in proper refrigerant handling techniques. The regulatory program helps to minimize the release of refrigerants, and in particular ozone depleting refrigerants such as chlorofluorocarbons and hydrofluorocarbons, as well as other regulated refrigerants as determined by Section 612. The licensure program complies with the requirements under the Montreal Protocol. The Environmental Protection Agency (EPA) published implementing regulations at 40 CFR Part 82.

Section 608 (together with Section 609, which covers motor vehicles) of the Clean Air Act serves as the main form of occupational licensure for technicians in the heating, ventilation, and air conditioning (HVAC) industry in the United States. The law requires that all persons who maintain, service, repair or dispose of appliances that contain regulated refrigerants be certified in proper refrigerant handling techniques. The regulatory program helps to minimize the release of refrigerants, and in particular ozone depleting refrigerants such as chlorofluorocarbons and hydrofluorocarbons, as well as other regulated refrigerants as determined by Section 612. The licensure program complies with the requirements under the Montreal Protocol. The Environmental Protection Agency (EPA) published implementing regulations at 40 CFR Part 82. ==Scope== There are four categories of certification: A technician with the required level of certification may also legally purchase regulated refrigerants. Technicians who violate the Clean Air Act provisions may be fined, lose their certification, and may be required to appear in Federal court. As of January 8, 2025, the maximum civil penalty for a Clean Air Act violation, including the knowing venting of regulated refrigerants prohibited under Section 608, is $124,426 per day per violation, an amount the EPA adjusts annually for inflation. ==Provisions== In general, along with general enforcement provisions, section 608 manages the following regulatory requirements: Technician certification Refrigerant recovery and recycling techniques and procedures Leak checking Sales restrictions and venting prohibitions - Listing of chemicals that fall under these requirements is part of the Significant New Alternatives Policy program Record keeping requirements Disposal and safety Reclamation Service practices. ==Credentialing and exams== EPA regulations require the test to be a "closed book" proctored exam. The only outside materials allowed are a temperature / pressure chart, scratch paper and a calculator. The certification exam contains 4 sections: Core, Type I, Type II, and Type III. Each section contains 25 multiple choice questions. The technician must achieve a passing score of 70% in each Type in which they are to be certified. All technicians must pass the CORE section before receiving any certification. A technician seeking certification must correctly answer 18 out of 25 questions on the CORE and at least one other section of the exam. A technician seeking Universal certification must correctly answer 18 out of 25 questions on each section of the exam. In addition to covering EPA (in particular, Section 608) regulations, the exam also covers basic safety and occupational practices, along with fundamental concepts of stratospheric ozone protection (which are typically part of the Core exam). Many universities and colleges also have associate degrees and apprenticeship programs that teach HVAC fundamentals along with providing EPA examinations. ==See also== Air Conditioning, Heating and Refrigeration Institute - In particular, standard 700 helps define levels of refrigerant reclamation, and standard 740 defines standards for recovery equipment ASHRAE - In particular, standard 15 helps define refrigerant safety groups HVAC Technical Standards Organizations Occupational licensure Ozone depletion Refrigerant reclamation Significant New Alternatives Policy ==References==

References

No reference rows published for this article.

Cite this article

MLA

"Section 608." encyclopegia.org, 2026, https://encyclopegia.org/wiki/section-608. Accessed 24 November 2026.

Chicago

"Section 608." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/section-608.

APA

encyclopegia.org. (2026). Section 608. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/section-608

Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON

CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1363368127 · 0.5 · snapshot enwiki-001363368127

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.