Spectrofluorometer
A spectrofluorometer is an instrument which takes advantage of fluorescent properties of some compounds in order to provide information regarding their concentration and chemical environment in a sample.[src] A certain excitation wavelength is selected, and the emission is observed either at a single wavelength, or a scan is performed to record the intensity versus wavelength, also called an emission spectrum.[src] The instrument is used in fluorescence spectroscopy.[src]
A spectrofluorometer is an instrument which takes advantage of fluorescent properties of some compounds in order to provide information regarding their concentration and chemical environment in a sample.[src] A certain excitation wavelength is selected, and the emission is observed either at a single wavelength, or a scan is performed to record the intensity versus wavelength, also called an emission spectrum.[src] The instrument is used in fluorescence spectroscopy.[src] ==Operation== Generally, spectrofluorometers use high intensity light sources to bombard a sample with as many photons as possible.[src] This allows for the maximum number of molecules to be in an excited state at any one point in time.[src] The light is either passed through a filter, selecting a fixed wavelength, or a monochromator, which allows a wavelength of interest to be selected for use as the exciting light.[src] The emission is collected at the perpendicular to the emitted light.[src] The emission is also either passed through a filter or a monochromator before being detected by a photomultiplier tube, photodiode, or charge-coupled device detector.[src] The signal can either be processed as digital or analog output.[src] Systems vary greatly and a number of considerations affect the choice.[src] The first is the signal-to-noise ratio.[src] There are many ways to look at the signal to noise of a given system but the accepted standard is by using the Raman signal of water.[src] Sensitivity or detection limit is another specification to be considered, that is how little light can be measured.[src] The standard would be fluorescein in NaOH, typical values for a high end instrument are in the femtomolar range.[src] ==Auxiliary components== These systems come with many options, including: Polarizers Peltier temperature controllers Cryostats Cold Finger Dewars Pulsed lasers for lifetime measurements LEDs for lifetimes Filter holders Adjustable optics (very important) Solid sample holders Slide holders Integrating spheres Near-infrared detectors Bilateral slits Manual slits Computer controlled slits Fast switching monochromators Filter wheels ==References==[src]
18 sentences · 18 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Spectrofluorometer." encyclopegia.org, 2025, https://encyclopegia.org/wiki/spectrofluorometer. Accessed 27 November 2026.
Chicago
"Spectrofluorometer." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/spectrofluorometer.
APA
encyclopegia.org. (2025). Spectrofluorometer. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/spectrofluorometer
Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON