Spreeta
Spreeta is an electro-optical device utilizing surface plasmon resonance to detect small changes in refractive index of liquids.[src] The Spreeta device was developed by Texas Instruments, Inc.[src] in the 1990s.[src] Device design incorporates a light-emitting diode (LED) illuminating a thin metal film (usually gold) in the Kretchmann geometry (needed to excite surface plasmons).[src] The reflected light is detected by a photodiode linear array (which translates angle of reflection to pixel position) and the resonance (a dip in the reflectivity at a specific angle of incidence) denotes the refractive index on the outer surface of the metal film.[src] Applications include real-time measurement of binding of antigens to antibodies attached to the sensor surface, monitoring changes in oil quality, and measuring sugar content in drinks (Brix level).[src] The term "Spreeta" is an anglic derivative of SPR-ITA, which combines SPR (for Surface Plasmon Resonance) with "ita" (a Spanish suffix meaning "small").[src] File:Spreeta Diagram and Sensors(1).jpg|The top image shows an optical diagram of the sensor (in cross-section).[src] The lower-left image is the original integrated sensor.[src] The lower-right image is a smaller version of the sensor with less sensitivity but more amiable to system integration.[src]
Spreeta is an electro-optical device utilizing surface plasmon resonance to detect small changes in refractive index of liquids.[src] The Spreeta device was developed by Texas Instruments, Inc.[src] in the 1990s.[src] Device design incorporates a light-emitting diode (LED) illuminating a thin metal film (usually gold) in the Kretchmann geometry (needed to excite surface plasmons).[src] The reflected light is detected by a photodiode linear array (which translates angle of reflection to pixel position) and the resonance (a dip in the reflectivity at a specific angle of incidence) denotes the refractive index on the outer surface of the metal film.[src] Applications include real-time measurement of binding of antigens to antibodies attached to the sensor surface, monitoring changes in oil quality, and measuring sugar content in drinks (Brix level).[src] The term "Spreeta" is an anglic derivative of SPR-ITA, which combines SPR (for Surface Plasmon Resonance) with "ita" (a Spanish suffix meaning "small").[src] File:Spreeta Diagram and Sensors(1).jpg|The top image shows an optical diagram of the sensor (in cross-section).[src] The lower-left image is the original integrated sensor.[src] The lower-right image is a smaller version of the sensor with less sensitivity but more amiable to system integration.[src]
20 sentences · 20 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Spreeta." encyclopegia.org, 2025, https://encyclopegia.org/wiki/spreeta. Accessed 26 November 2026.
Chicago
"Spreeta." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/spreeta.
APA
encyclopegia.org. (2025). Spreeta. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/spreeta
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON