Stigmator
A stigmator is a component of electron microscopes that reduces astigmatism of the beam by imposing a weak electric or magnetic quadrupole field on the electron beam.[src]
A stigmator is a component of electron microscopes that reduces astigmatism of the beam by imposing a weak electric or magnetic quadrupole field on the electron beam.[src] ==Background== For early electron microscopes - between the 1940s and 1960s - astigmatism was one of the main performance limiting factors.[src] Sources of this astigmatism include misaligned objectives, non-uniform magnetic fields in the lenses (which were especially hard to correct), imperfectly circular lenses, and contamination on the objective aperture.[src] Therefore, to improve resolution, the astigmatism had to be corrected.[src] The first stigmators used in commercial electron microscopes were introduced in the early 1960s.[src] The stigmatic correction is done using an electric or magnetic field perpendicular to the beam.[src] By adjusting the magnitude and azimuth of the stigmator field, asymmetric astigmatization can be compensated for.[src] Stigmators produce weak fields compared to the electromagnetic lenses they correct, as usually only minor correction are necessary.[src] ==Number of poles== Stigmators create a quadrupole field, and thus have to consist of at least four poles, but hexapole, octopole and dodecapole stigmatizors are also used, with octopole stigmators being the most common.[src] The octopole (or higher order of poles) stigmatizers also produce a quadrupole field, but use their additional poles to align the imposed field with the direction of the stigmatization ellipticity.[src] ==Types== ===Magnetic stigmator=== The magnetic stigmator is a weak cylindrical lens that can correct the cylindrical component of the beam.[src] It can consist of metal rods which induce a magnetic field, which are inserted with their long axis towards the beam center.[src] By retracting or extending the rods, the astigmatism can be compensated.[src] ===Electromagnetic=== Electromagnetic stigmators are stigmators that are integrated with the lenses and directly deform the magnetic field of the lens(es).[src] These were the first types of stigmators to be used.[src] ==Automatic stigmators== In most cases, the astigmatism can be corrected using a constant stigmator field which is adjusted by the microscope operator.[src] The main cause of astigmatism, the non-uniform magnetic field produced by the lenses, usually does not change noticeable during a TEM session.[src] A recent development are computer-controlled stigmators, which usually use the Fourier transform of the image to find the ideal stigmator setting.[src] The Fourier transform of an astigmatic image is usually elliptically shaped.[src] For a stigmatic image, it is round, this property can be used by algorithms to reduce the astigmatic aberration.[src] ==Multiple stigmator systems== Normally, one stigmator is sufficient, but TEMs normally contain three stigmators: one to stigmatize the source beam, one to stigmatize real-space images, and one to stigmatize diffraction patterns.[src] These are commonly referred to as condensor, objective, and intermediate (or diffraction) stigmators.[src] The use of three post-sample stigmators is proposed to reduce linear distortion ==See also== Anastigmat, a photographic lens completely corrected for the three main optical aberrations ==References==[src]
24 sentences · 24 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Stigmator." encyclopegia.org, 2026, https://encyclopegia.org/wiki/stigmator. Accessed 26 November 2026.
Chicago
"Stigmator." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/stigmator.
APA
encyclopegia.org. (2026). Stigmator. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/stigmator
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON