Suparnostic
suPARnostic is a simplified double monoclonal antibody sandwich enzyme-linked immunosorbent assay (ELISA) that measures the amount of soluble urokinase plasminogen activator receptor (suPAR) in blood.[src] Elevated plasma suPAR levels have been observed in various infectious, inflammatory and autoimmune diseases.[src] suPAR concentration positively correlates to the activation level of the immune system.[src] suPARnostic can be used as a prognostic tool to determine the severity of a disease within a patient, but is not used as a reliable diagnostic tool, as it can detect the severity of the immune response in a patient, but does not reveal the specific disease from which the patient may be suffering.[src] Recently, increase suPAR levels were shown to be associated with increased risk of systemic inflammatory response syndrome (SIRS)/sepsis, cardiovascular disease, type 2 diabetes, infectious diseases, HIV, cancer tuberculosis, malaria, bacterial and viral CNS infections, rheumatoid arthritis, multiple sclerosis and mortality in the general population.[src]
suPARnostic is a simplified double monoclonal antibody sandwich enzyme-linked immunosorbent assay (ELISA) that measures the amount of soluble urokinase plasminogen activator receptor (suPAR) in blood.[src] Elevated plasma suPAR levels have been observed in various infectious, inflammatory and autoimmune diseases.[src] suPAR concentration positively correlates to the activation level of the immune system.[src] suPARnostic can be used as a prognostic tool to determine the severity of a disease within a patient, but is not used as a reliable diagnostic tool, as it can detect the severity of the immune response in a patient, but does not reveal the specific disease from which the patient may be suffering.[src] Recently, increase suPAR levels were shown to be associated with increased risk of systemic inflammatory response syndrome (SIRS)/sepsis, cardiovascular disease, type 2 diabetes, infectious diseases, HIV, cancer tuberculosis, malaria, bacterial and viral CNS infections, rheumatoid arthritis, multiple sclerosis and mortality in the general population.[src] ==Performing the suPARnostic ELISA== Performing the suPARnostic ELISA requires two antibodies with high specificity for suPAR.[src] The blood plasma sample from the patient that contains an unknown amount of suPAR is immobilized on the microwells on the clear microtiter plate and a detection antibody forms a complex with suPAR.[src] Between each step the plate is rinsed with a wash buffer to dispose of any proteins that do not specifically bind to any of the wells on the plate.[src] After the final wash step, the plate is developed by adding the TMB substrate to produce a visible signal, which indicates the quantity of suPAR in the sample.[src] The measured absorbance can, based on the values from the standard curve, be converted to the concentration (ng/mL) of suPAR in the sample.[src] This level can then suggest whether or not the patient is experiencing challenges to their immune system.[src] ==Principles== The suPARnostic ELISA is a simplified double monoclonal antibody sandwich assay that measures the level of suPAR and suPAR II-III in the body .[src] The suPARnostic ELISA utilizes monoclonal mouse and rat antibodies against human suPAR.[src] The advantages of using monoclonal antibodies compared to using polyclonal antibodies includes: High homogeneity, absence of nonspecific antibodies and no batch-to-batch or lot-to-lot variability.[src] This results in a very robust and reliable assay.[src] A 'sandwich' is formed of solid-phase antibody, suPAR and peroxidase-conjugated antibody.[src] The concentration (ng/mL plasma) of suPAR in the patient sample is determined via interpolation, based on a calibration curve prepared from seven suPAR standards.[src] Recombinant suPAR standards are calibrated against healthy human blood donor samples.[src] Absorbance is measured using a microtiter plate reader, at 450 nm with a 650 nm reference filter.[src] Measurement of suPAR levels from blood samples provides greater accuracy and precision than measurement from urine or cerebral spinal fluid.[src] suPAR level is not changed by transient illness such as cold.[src] It also remains stable after a blood sample is taken despite storage.[src] suPARnostic measurements between 0.1 and 4.0 ng/mL suggest that a patient is healthy, with no challenges to their immune system and no signs or symptoms of an opportunistic infection or inflammation; the average level among the population is 3.4 ng/mL.[src] However, a patient's immune system can be considered 'negatively activated' at suPAR levels above 4.0 and up to 6.0 ng/mL, indicating a potential infection or high level of inflammation.[src] In this case, a patient's health is likely to worsen and he or she should be referred for further testing.[src] suPARnostic measurements from 6.0 ng/mL to double digit levels can indicate a serious illness that is progressing rapidly to a critical situation.[src] Patients in the intensive care unit average a level of 10.0 ng/mL.[src] There is no difference in suPAR levels intrinsic to various races; however, the scale varies for male and female.[src] There are two suPARnostic tests available.[src] The suPARnostic Standard ELISA (Code No.[src] A001) is for research use and large trials, one batch consisting of 41 samples in doublets.[src] The suPARnostic Flex ELISA (Code No.[src] A002) has been developed for clinical applications consisting of 93 samples, is modular and flexible, and gives fully quantitative results in 2 hours.[src] ==Practical Considerations== The suPARnostic kit has a refrigerated shelf life of several years and when frozen, may be kept for longer.[src] The kit should sit at room temperature for half an hour before use but it may be held at room temperature for as long as three to four hours.[src] The suPARnostic Flex ELISA (Code No.[src] A002) is able to provide fully quantitative results in 2 hours.[src] suPARnostic is run as large, batch test with up to 41 samples in doublets for research purposes or 93 samples for clinical use at one time.[src] Although suPARnostic currently does not have FDA approval, it is CE/IVD marked for distribution throughout Europe.[src] suPAR is a prognostic test to indicate general health, and it cannot be used as a diagnostic tool to suggest a particular illness.[src] suPAR cannot be used in the detection of brain tumors because the suPAR molecule cannot migrate through the blood brain barrier.[src] ==References==[src]
47 sentences · 47 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Suparnostic." encyclopegia.org, 2024, https://encyclopegia.org/wiki/suparnostic. Accessed 25 November 2026.
Chicago
"Suparnostic." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/suparnostic.
APA
encyclopegia.org. (2024). Suparnostic. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/suparnostic
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON