Supercapacitor
for PCB mounting used for industrial applications A supercapacitor (SC), also called an ultracapacitor, is a high-capacity capacitor, with a capacitance value much higher than solid-state capacitors but with lower voltage limits.[src] It bridges the gap between electrolytic capacitors and rechargeable batteries.[src] It typically stores 10 to 100 times more energy per unit mass or energy per unit volume than electrolytic capacitors, can accept and deliver charge much faster than batteries, and tolerates many more charge and discharge cycles than rechargeable batteries.[src] Unlike ordinary capacitors, supercapacitors do not use a conventional solid dielectric, but rather, they use electrostatic double-layer capacitance and electrochemical pseudocapacitance, both of which contribute to the total energy storage of the capacitor.[src] Supercapacitors are used in applications requiring many rapid charge/discharge cycles, rather than long-term compact energy storage: in automobiles, buses, trains, cranes, and elevators they are used for regenerative braking, short-term energy storage, or burst-mode power delivery.[src] Smaller units are used as power backup for static random-access memory (SRAM).[src]
for PCB mounting used for industrial applications A supercapacitor (SC), also called an ultracapacitor, is a high-capacity capacitor, with a capacitance value much higher than solid-state capacitors but with lower voltage limits.[src] It bridges the gap between electrolytic capacitors and rechargeable batteries.[src] It typically stores 10 to 100 times more energy per unit mass or energy per unit volume than electrolytic capacitors, can accept and deliver charge much faster than batteries, and tolerates many more charge and discharge cycles than rechargeable batteries.[src] Unlike ordinary capacitors, supercapacitors do not use a conventional solid dielectric, but rather, they use electrostatic double-layer capacitance and electrochemical pseudocapacitance, both of which contribute to the total energy storage of the capacitor.[src] Supercapacitors are used in applications requiring many rapid charge/discharge cycles, rather than long-term compact energy storage: in automobiles, buses, trains, cranes, and elevators they are used for regenerative braking, short-term energy storage, or burst-mode power delivery.[src] Smaller units are used as power backup for static random-access memory (SRAM).[src] C_\mathrm{total} = \frac{C_1 \cdot C_2}{C_1 + C_2}.[src] Supercapacitors may have either symmetric or asymmetric electrodes.[src] Symmetry implies that both electrodes have the same capacitance value, yielding a total capacitance of half the value of each single electrode (if , then ).[src] For asymmetric capacitors, the total capacitance can be taken as that of the electrode with the smaller capacitance (if , then ).[src] C= \varepsilon\frac{A}{d}.[src] Accordingly, capacitance is greatest in capacitors made from materials with a high permittivity , large electrode plate surface areas and small distance between plates .[src] As a result, double-layer capacitors have much higher capacitance values than conventional capacitors, arising from the extremely large surface area of activated carbon electrodes and the extremely thin double-layer distance on the order of a few ångströms ( ), of order of the Debye length.[src] Assuming that the minimum distance between the electrode and the charge accumulating region cannot be less than the typical distance between negative and positive charges in atoms of a general capacitance upper limit of has been predicted for non-faradaic capacitors.[src] The main drawback of carbon electrodes of double-layer supercapacitors is small values of quantum capacitance which act in series with capacitance of ionic space charge.[src] Therefore, further increase of density of capacitance in SCs can be connected with increasing of quantum capacitance of carbon electrode nanostructures.[src] The amount of charge stored per unit voltage in an electrochemical capacitor is primarily a function of the electrode size.[src] The electrostatic storage of energy in the double-layers is linear with respect to the stored charge, and correspond to the concentration of the adsorbed ions.[src] Also, while charge in conventional capacitors is transferred via electrons, capacitance in double-layer capacitors is related to the limited moving speed of ions in the electrolyte and the resistive porous structure of the electrodes.[src] Since no chemical changes take place within the electrode or electrolyte, charging and discharging electric double-layers in principle is unlimited.[src] Real supercapacitors lifetimes are only limited by electrolyte evaporation effects.[src] W=\frac{1}{2}\cdot C_\text{DC} \cdot V_\text{DC}^2 This value is also called the "DC capacitance".[src] C_\text{total} = I_\text{discharge} \cdot \frac{t_2-t_1}{V_1-V_2} The value of the discharge current is determined by the application.[src] The IEC standard defines four classes: Memory backup, discharge current in mA = 1 • C (F) Energy storage, discharge current in mA = 0,4 • C (F) • V (V) Power, discharge current in mA = 4 • C (F) • V (V) Instantaneous power, discharge current in mA = 40 • C (F) • V (V) The measurement methods employed by individual manufacturers are mainly comparable to the standardized methods.[src] The standardized measuring method is too time-consuming for manufacturers to use during production for each individual component.[src] For industrial-produced capacitors, the capacitance value is instead measured with a faster, low-frequency AC voltage, and a correlation factor is used to compute the rated capacitance.[src] This frequency dependence affects capacitor operation.[src] Rapid charge and discharge cycles mean that neither the rated capacitance value nor specific energy are available.[src] In this case the rated capacitance value is recalculated for each application condition.[src] The time t a supercapacitor can deliver a constant current I can be calculated as: t=\frac{C\cdot (U_\text{charge}-U_\text{min}) }{I} as the capacitor voltage decreases from U charge down to U min .[src] If the application needs a constant power P for a certain time t this can be calculated as: t=\frac{1}{2 P}\cdot C\cdot(U_\text{charge}^2-U_\text{min}^2).[src] wherein also the capacitor voltage decreases from U charge down to U min .[src] R_\text{i}= \frac{\Delta V_2}{I_\text{discharge}} The discharge current I discharge for the measurement of internal resistance can be taken from the classification according to IEC 62391-1.[src] This internal DC resistance R i should not be confused with the internal AC resistance called equivalent series resistance (ESR) normally specified for capacitors.[src] It is measured at 1 kHz.[src] ESR is much smaller than DC resistance.[src] ESR is not relevant for calculating supercapacitor inrush currents or other peak currents.[src] R i determines several supercapacitor properties.[src] It limits the charge and discharge peak currents as well as charge/discharge times.[src] R i and the capacitance C results in the time constant \tau \tau = R_\text{i} \cdot C This time constant determines the charge/discharge time.[src] A 100 F capacitor with an internal resistance of 30 mΩ for example, has a time constant of 0.03 • 100 = 3 s.[src] After 3 seconds charging with a current limited only by internal resistance, the capacitor has 63.2% of full charge (or is discharged to 36.8% of full charge).[src] Standard capacitors with constant internal resistance fully charge during about 5 \tau .[src] Since internal resistance increases with charge/discharge, actual times cannot be calculated with this formula.[src] Thus, charge/discharge time depends on specific individual construction details.[src] P_\text{loss} = R_\text{i} \cdot I^2 This heat must be released and distributed to the ambient environment to maintain operating temperatures below the specified maximum temperature.[src] Heat generally defines capacitor lifetime due to electrolyte diffusion.[src] The heat generation coming from current loads should be smaller than 5 to 10 K at maximum ambient temperature (which has only minor influence on expected lifetime).[src] For that reason the specified charge and discharge currents for frequent cycling are determined by internal resistance.[src] The specified cycle parameters under maximal conditions include charge and discharge current, pulse duration and frequency.[src] They are specified for a defined temperature range and over the full voltage range for a defined lifetime.[src] They can differ enormously depending on the combination of electrode porosity, pore size and electrolyte.[src] Generally a lower current load increases capacitor life and increases the number of cycles.[src] This can be achieved either by a lower voltage range or slower charging and discharging.[src] Supercapacitors (except those with polymer electrodes) can potentially support more than one million charge/discharge cycles without substantial capacity drops or internal resistance increases.[src] Beneath the higher current load is this the second great advantage of supercapacitors over batteries.[src] The stability results from the dual electrostatic and electrochemical storage principles.[src] The specified charge and discharge currents can be significantly exceeded by lowering the frequency or by single pulses.[src] Heat generated by a single pulse may be spread over the time until the next pulse occurs to ensure a relatively small average heat increase.[src] Such a "peak power current" for power applications for supercapacitors of more than 1000 F can provide a maximum peak current of about 1000 A.[src] Such high currents generate high thermal stress and high electromagnetic forces that can damage the electrode-collector connection requiring robust design and construction of the capacitors.[src] W_\text{max}=\frac{1}{2}\cdot C_\text{total} \cdot V_\text{loaded}^2 This formula describes the amount of energy stored and is often used to describe new research successes.[src] However, only part of the stored energy is available to applications, because the voltage drop and the time constant over the internal resistance mean that some of the stored charge is inaccessible.[src] The effective realized amount of energy W eff is reduced by the used voltage difference between V max and V min and can be represented as: W_\text{eff}=\frac{1}{2}\ C \cdot\ ( V_\text{max}^2 - V_\text{min}^2 ) This formula also represents the energy asymmetric voltage components such as lithium ion capacitors.[src] P_\text{eff}=\frac{1}{8}\cdot\frac{V^2}{R_i} , P_\text{max}=\frac{1}{4}\cdot\frac{V^2}{R_i} with V = voltage applied and R i , the internal DC resistance of the capacitor.[src] Just like specific energy, specific power is measured either gravimetrically in kilowatts per kilogram (kW/kg, specific power) or volumetrically in kilowatts per litre (kW/L, power density).[src] Supercapacitor specific power is typically 10 to 100 times greater than for batteries and can reach values up to 15 kW/kg.[src] Ragone charts relate energy to power and are a valuable tool for characterizing and visualizing energy storage components.[src] With such a diagram, the position of specific power and specific energy of different storage technologies is easily to compare, see diagram.[src] L_x =L_0\cdot 2^\frac{T_0-T_x}{10} With: L x = estimated lifetime L 0 = specified lifetime T 0 = upper specified capacitor temperature T x = actual operating temperature of the capacitor cell Calculated with this formula, capacitors specified with 5000 h at 65 °C, have an estimated lifetime of 20,000 h at 45 °C.[src] Lifetimes are also dependent on the operating voltage, because the development of gas in the liquid electrolyte depends on the voltage.[src] The lower the voltage, the smaller the gas development, and the longer the lifetime.[src] No general formula relates voltage to lifetime.[src] The voltage dependent curves shown from the picture are an empirical result from one manufacturer.[src] Life expectancy for power applications may be also limited by current load or number of cycles.[src] This limitation has to be specified by the relevant manufacturer and is strongly type dependent.[src]
82 sentences · 82 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Supercapacitor." encyclopegia.org, 2026, https://encyclopegia.org/wiki/supercapacitor. Accessed 26 November 2026.
Chicago
"Supercapacitor." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/supercapacitor.
APA
encyclopegia.org. (2026). Supercapacitor. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/supercapacitor
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON