tomosynthesis

.[src] Tomosynthesis, also digital tomosynthesis (DTS), is a method for performing high-resolution limited-angle tomography at radiation dose levels comparable with projectional radiography.[src] It has been studied for a variety of clinical applications, including vascular imaging, dental imaging, orthopedic imaging, mammographic imaging, musculoskeletal imaging, and chest imaging.[src]

.[src] Tomosynthesis, also digital tomosynthesis (DTS), is a method for performing high-resolution limited-angle tomography at radiation dose levels comparable with projectional radiography.[src] It has been studied for a variety of clinical applications, including vascular imaging, dental imaging, orthopedic imaging, mammographic imaging, musculoskeletal imaging, and chest imaging.[src] ==History== The concept of tomosynthesis was derived from the work of Ziedses des Plantes, who developed methods of reconstructing an arbitrary number of planes from a set of projections.[src] Though this idea was displaced by the advent of computed tomography, tomosynthesis later gained interest as a low-dose tomographic alternative to CT.[src] ==Reconstruction== Tomosynthesis reconstruction algorithms are similar to CT reconstructions, in that they are based on performing an inverse Radon transform.[src] Due to partial data sampling with very few projections, approximation algorithms have to be used.[src] Filtered back projection and iterative, expectation-maximization algorithms have both been used to reconstruct the data.[src] Reconstruction algorithms for tomosynthesis are different from those of conventional CT because the conventional filtered back projection algorithm requires a complete set of data.[src] Iterative algorithms based upon expectation maximization are most commonly used, but are computationally intensive.[src] Some manufacturers have produced practical systems using off-the-shelf GPUs to perform the reconstruction in a few seconds.[src] ==Differences from other imaging modalities== Digital tomosynthesis combines digital image capture and processing with simple tube/detector motion as used in conventional computed tomography (CT).[src] However, though there are some similarities to CT, it is a separate technique.[src] In modern (helical) CT, the source/detector makes at least a complete 180-degree rotation about the subject obtaining a complete set of data from which images may be reconstructed.[src] Digital tomosynthesis, on the other hand, only uses a limited rotation angle (e.g., 15-60 degrees) with a lower number of discrete exposures (e.g., 7-51) than CT.[src] This incomplete set of projections is digitally processed to yield images similar to conventional tomography with a limited depth of field.[src] Because the image processing is digital, a series of slices at different depths and with different thicknesses can be reconstructed from the same acquisition.[src] However, since fewer projections are needed than CT to perform the reconstruction, radiation exposure and cost are both reduced.[src] ==Applications== ===Chest=== ===Musculoskeletal imaging=== Tomosynthesis has a much more limited depth of field than does CT.[src] For this reason, it likely will not be able to replace CT for the evaluation of the deeper organs of the body.[src] However, since bones are often near the skin, multiple musculoskeletal applications of tomosynthesis have been studied, most of which have mostly been used in research with limited use in everyday practice.[src] ====Evaluation of fractures==== Tomosynthesis has been compared to both radiography and CT for the evaluation of healing fractures, especially in the presence of hardware.[src] In a study of patients with wrist fractures, digital tomosynthesis was shown to enable detection of more fractures than radiography while simultaneously providing lower metal artifact than radiography.[src] ====Evaluation of erosions in rheumatoid arthritis==== Tomosynthesis has been compared to digital radiography, with CT as the standard, for the detection of erosions associated with rheumatoid arthritis.[src] The radiation dose of digital tomosynthesis was very close to that of digital radiography.[src] However, tomosynthesis showed sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 80%, 75%, 78%, 76%, and 80%, compared to digital radiography were 66%, 81%, 74%, 77%, and 71%.[src] The slight benefit digital tomosynthesis in this application may or may not justify the slightly increased cost of the modality compared to digital radiography.[src] ===Electronics=== Tomosynthesis is also used for x-ray inspection of electronics, particularly printed circuit board assemblies and electronic components.[src] Tomosynthesis is usually used where a CT slice is required at high magnification, where conventional CT would not allow the sample to be located close enough to the x-ray source.[src] ==References== ==External links== Digital Tomosynthesis: Advanced Breast Cancer Imaging Technique, by Max Wiedmann, UCSB[src]

33 sentences · 33 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"tomosynthesis." encyclopegia.org, 2026, https://encyclopegia.org/wiki/tomosynthesis. Accessed 25 November 2026.

Chicago

"tomosynthesis." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/tomosynthesis.

APA

encyclopegia.org. (2026). tomosynthesis. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/tomosynthesis

Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON

CC BY-SA 4.0 · tier1-factual · https://en.wikipedia.org/w/index.php?oldid=1378273275 · 0.55 · snapshot tomosynthesis-879616-3216028626a79ace · QID Q7820316

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.