Tomotherapy
Tomotherapy is a type of radiation therapy treatment machine.[src] In tomotherapy a thin radiation beam is modulated as it rotates around the patient, while they are moved through the bore of the machine.[src] The name comes from the use of a strip-shaped beam, so that only one "slice" (Greek prefix "tomo-") of the target is exposed at any one time by the radiation.[src] The external appearance of the system and movement of the radiation source and patient can be considered analogous to a CT scanner (computed tomography), which uses lower doses of radiation for imaging.[src] Like a conventional machine used for X-ray external beam radiotherapy (often referred to as a linear accelerator or linac, their main component), it [the tomotherapy machine] generates the radiation beam, but the external appearance of the machine, patient positioning, and treatment delivery differ.[src] Conventional linacs do not work on a slice-by-slice basis but typically have a large area beam which can also be resized and modulated.[src]
Tomotherapy is a type of radiation therapy treatment machine.[src] In tomotherapy a thin radiation beam is modulated as it rotates around the patient, while they are moved through the bore of the machine.[src] The name comes from the use of a strip-shaped beam, so that only one "slice" (Greek prefix "tomo-") of the target is exposed at any one time by the radiation.[src] The external appearance of the system and movement of the radiation source and patient can be considered analogous to a CT scanner (computed tomography), which uses lower doses of radiation for imaging.[src] Like a conventional machine used for X-ray external beam radiotherapy (often referred to as a linear accelerator or linac, their main component), it [the tomotherapy machine] generates the radiation beam, but the external appearance of the machine, patient positioning, and treatment delivery differ.[src] Conventional linacs do not work on a slice-by-slice basis but typically have a large area beam which can also be resized and modulated.[src] ==General principles== The treatment field's length (the width of the radiation slice) is adjustable using collimator jaws.[src] In static-jaw delivery, the field length remains constant during a treatment; in dynamic-jaw delivery, the field length changes so that it begins and ends at its minimum setting.[src] Tomotherapy treatment times vary compared to normal radiation therapy treatment times.[src] Tomotherapy treatment times can be as low as 6.5 minutes for common prostate treatment, excluding extra time for imaging.[src] Modern tomotherapy and conventional linac systems incorporate one or both of megavoltage X-ray or kilovoltage X-ray imaging systems, enabling image-guided radiation therapy (IGRT).[src] In tomotherapy, images are acquired in a very similar manner to a CT scanner, thanks to their closely related design.[src] There are few head-to-head comparisons of tomotherapy and other IMRT techniques, however there is some evidence that a conventional linac using VMAT can provide faster treatment whereas tomotherapy is better able to spare surrounding healthy tissue while delivering a uniform dose.[src] ==Clinical considerations== Lung cancer, head and neck tumors, breast cancer, prostate cancer, stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) are some examples of treatments commonly performed using tomotherapy.[src] In general, radiation therapy (or radiotherapy) has developed with a strong reliance on homogeneity of dose throughout the tumor.[src] Tomotherapy embodies the sequential delivery of radiation to different parts of the tumor which raises two important issues.[src] First, this method is known as "field matching" and brings with it the possibility of a less-than-perfect match between two adjacent fields with a resultant hot and/or cold spot within the tumor.[src] The second issue is that if the patient or tumor moves during this sequential delivery, then again, a hot or cold spot will result.[src] The first problem is reduced by use of a helical motion, as in spiral computed tomography.[src] Some research has suggested tomotherapy provides more conformal treatment plans and decreased acute toxicity.[src] Non-helical static beam techniques such as IMRT and TomoDirect are well suited to whole breast radiation therapy.[src] These treatment modes avoid the low-dose integral splay and long treatment times associated with helical approaches by confining dose delivery to tangential angles.[src] This risk is accentuated in younger patients with early-stage breast cancer, where cure rates are high and life expectancy is substantial.[src] Static beam angle approaches aim to maximize the therapeutic ratio by ensuring that the tumor control probability (TCP) significantly outweighs the associated normal tissue complication probability (NTCP).[src] ==History== The tomotherapy technique was developed in the early 1990s at the University of Wisconsin–Madison by Professor Thomas Rockwell Mackie and Paul Reckwerdt.[src] A small megavoltage x-ray source was mounted in a similar fashion to a CT x-ray source, and the geometry provided the opportunity to provide CT images of the body in the treatment setup position.[src] Although original plans were to include kilovoltage CT imaging, current models use megavoltage energies.[src] With this combination, the unit was one of the first devices capable of providing modern image-guided radiation therapy (IGRT).[src] The first implementation of tomotherapy was the Corvus system developed by Nomos Corporation, with the first patient treated in April 1994.[src] This was the first commercial system for planning and delivering intensity modulated radiation therapy (IMRT).[src] The original system, designed solely for use in the brain, incorporated a rigid skull-based fixation system to prevent patient motion between the delivery of each slice of radiation.[src] But some users eschewed the fixation system and applied the technique to tumors in many different parts of the body.[src] ===Mobile tomotherapy=== Due to their internal shielding and small footprint, TomoTherapy Hi-Art and TomoTherapy TomoHD treatment machines were the only high energy radiotherapy treatment machines used in relocatable radiotherapy treatment suites.[src] Two different types of suites were available: TomoMobile developed by TomoTherapy Inc.[src] which was a moveable truck; and Pioneer, developed by UK-based Oncology Systems Limited.[src] The latter was developed to meet the requirements of UK and European transport law requirements and was a contained unit placed on a concrete pad, delivering radiotherapy treatments in less than five weeks.[src] ==See also== Radiation therapy Radiosurgery[src]
43 sentences · 43 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Tomotherapy." encyclopegia.org, 2026, https://encyclopegia.org/wiki/tomotherapy. Accessed 25 November 2026.
Chicago
"Tomotherapy." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/tomotherapy.
APA
encyclopegia.org. (2026). Tomotherapy. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/tomotherapy
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON