Trabectome

The Trabectome is a surgical device that can be used for ab interno trabeculotomy, a minimally invasive glaucoma surgery for the surgical management of adult, juvenile, and infantile glaucoma.[src] The trabecular meshwork is a major site of resistance to aqueous humor outflow.[src] As angle surgeries such as Trabectome follow the physiologic outflow pathway, the risk of complications is significantly lower than filtering surgeries.[src] Hypotony with damage to the macula (hypotony maculopathy), can occur with pressures below 5 mmHg, for instance, after traditional trabeculectomy, because of the episcleral venous pressure limit.[src] The Trabectome handpiece is inserted into the anterior chamber, its tip positioned into Schlemm's canal, and advanced to the left and to the right.[src] Different from cautery, the tip generates plasma to molecularize the trabecular meshwork and remove it drag-free and with minimal thermal effect.[src] Active irrigation of the trabectome surgery system helps to keep the anterior chamber formed during the procedure and precludes the need for ophthalmic viscoelastic devices.[src] Viscoelastic devices tend to trap debris or gas bubbles and diminish visualization.[src] The Trabectome decreases the intra-ocular pressure typically to a mid-teen range and reduces the patient's requirement to take glaucoma eye drops and glaucoma medications (see references).…[src]

The Trabectome is a surgical device that can be used for ab interno trabeculotomy, a minimally invasive glaucoma surgery for the surgical management of adult, juvenile, and infantile glaucoma.[src] The trabecular meshwork is a major site of resistance to aqueous humor outflow.[src] As angle surgeries such as Trabectome follow the physiologic outflow pathway, the risk of complications is significantly lower than filtering surgeries.[src] Hypotony with damage to the macula (hypotony maculopathy), can occur with pressures below 5 mmHg, for instance, after traditional trabeculectomy, because of the episcleral venous pressure limit.[src] The Trabectome handpiece is inserted into the anterior chamber, its tip positioned into Schlemm's canal, and advanced to the left and to the right.[src] Different from cautery, the tip generates plasma to molecularize the trabecular meshwork and remove it drag-free and with minimal thermal effect.[src] Active irrigation of the trabectome surgery system helps to keep the anterior chamber formed during the procedure and precludes the need for ophthalmic viscoelastic devices.[src] Viscoelastic devices tend to trap debris or gas bubbles and diminish visualization.[src] The Trabectome decreases the intra-ocular pressure typically to a mid-teen range and reduces the patient's requirement to take glaucoma eye drops and glaucoma medications (see references).[src] The theoretically lowest pressure that can be achieved is equal to 8 mmHg in the episcleral veins.[src] This procedure is performed through a small incision and can be done on an outpatient basis.[src] By removing the primary resistance (the trabecular meshwork), aqueous humor can pass more freely into collector channels and aqueous veins.[src] The Goldmann equation states that Intraocular Pressure = [Aqueous Humor Formation/Outflow] + Episcleral Venous Pressure.[src] This equation states that free-flowing aqueous humor should cause intraocular pressure to drop to the same level as in the episcleral veins [26].[src] However, this is rare, and the average postoperative intraocular pressure is around 16 mmHg [27].[src] Spectral domain optical coherence tomography can be used to view collector channel diameter change, collapse or patency.[src] Like human eyes, pig eyes have more outflow along the nasal drainage system than the temporal angle.[src] Trabecular meshwork removal from the nasal can enhance outflow beyond physiological levels.[src] It can also cause fluorescein to flow circumferentially, through small connections between Schlemm's canal-like segments, typical of a pig's angular aqueous plexus [3-5].[src] Reconstruction of outflow tracts via spectral domain optical coherence tomography have confirmed a correlation between aqueous spaces and collectors where flow was seen.[src] However, these studies have also confirmed the existence of non-perfused vascular structures that could be part of the arterial or venous vascular system, or poorly perfused collector channels.[src] Recent discoveries have shown valve-like structures that appear to guard collector channel orifices and collapsible aqueous veins 9, 10.[src] These findings contradict the view that collector channel openings are round and unobstructed.[src] Structural data has shown that flaps are suspended by string-like attachments.[src] This research suggests that these attachments should be maintained during surgery, or that the flaps at the opening of collector channels should be removed.[src] Electron microscopic images of the outer wall suggest that most are removed during trabectome procedures, together with their attachments and the trabecular meshwork [30].[src]

35 sentences · 35 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Trabectome." encyclopegia.org, 2026, https://encyclopegia.org/wiki/trabectome. Accessed 25 November 2026.

Chicago

"Trabectome." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/trabectome.

APA

encyclopegia.org. (2026). Trabectome. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/trabectome

Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON

CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1334830498 · 0.5 · snapshot enwiki-001334830498

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.