encyclopegia.org

Voltmeter

A voltmeter is an instrument used for measuring electric potential difference between two points in an electric circuit. It is connected in parallel. It usually has a high resistance so that it takes negligible current from the circuit. Analog voltmeters move a pointer across a scale in proportion to the voltage measured and can be built from a galvanometer and series resistor. Meters using amplifiers can measure tiny voltages of microvolts or less. Digital voltmeters give a numerical display of voltage by use of an analog-to-digital converter. Voltmeters are made in a wide range of styles, some separately powered (e.g. by battery), and others powered by the measured voltage source itself. Instruments permanently mounted in a panel are used to monitor generators or other fixed apparatus. Portable instruments, usually equipped to also measure current and resistance in the form of a multimeter are standard test instruments used in electrical and electronics work. Any measurement that can be converted to a voltage can be displayed on a meter that is suitably calibrated; for example, pressure, temperature, flow or level in a chemical process plant. General-purpose analog voltmeters may have an accuracy of a few percent of full scale and are used with voltages from a fraction of a volt to several thousand volts.…

A voltmeter is an instrument used for measuring electric potential difference between two points in an electric circuit. It is connected in parallel. It usually has a high resistance so that it takes negligible current from the circuit. Analog voltmeters move a pointer across a scale in proportion to the voltage measured and can be built from a galvanometer and series resistor. Meters using amplifiers can measure tiny voltages of microvolts or less. Digital voltmeters give a numerical display of voltage by use of an analog-to-digital converter. Voltmeters are made in a wide range of styles, some separately powered (e.g. by battery), and others powered by the measured voltage source itself. Instruments permanently mounted in a panel are used to monitor generators or other fixed apparatus. Portable instruments, usually equipped to also measure current and resistance in the form of a multimeter are standard test instruments used in electrical and electronics work. Any measurement that can be converted to a voltage can be displayed on a meter that is suitably calibrated; for example, pressure, temperature, flow or level in a chemical process plant. General-purpose analog voltmeters may have an accuracy of a few percent of full scale and are used with voltages from a fraction of a volt to several thousand volts. Digital meters can be made with high accuracy, typically better than 1%. Specially calibrated test instruments have higher accuracies, with laboratory instruments capable of measuring to accuracies of a few parts per million. Part of the problem of making an accurate voltmeter is that of calibration to check its accuracy. In laboratories, the Weston cell is used as a standard voltage for precision work. Precision voltage references are available based on electronic circuits. ==Schematic symbol== In circuit diagrams, a voltmeter is represented by the letter V in a circle, with two emerging lines representing the two points of measurement. ==Analog voltmeter== of the d'Arsonval type. A moving coil galvanometer can be used as a voltmeter by inserting a resistor in series with the instrument. The galvanometer has a coil of fine wire suspended in a strong magnetic field. When an electric current is applied, the interaction of the magnetic field of the coil and of the stationary magnet creates a torque, tending to make the coil rotate. The torque is proportional to the current through the coil. The coil rotates, compressing a spring that opposes the rotation. The deflection of the coil is thus proportional to the current, which in turn is proportional to the applied voltage, which is indicated by a pointer on a scale. One of the design objectives of the instrument is to disturb the circuit as little as possible and so the instrument should draw a minimum of current to operate. This is achieved by using a sensitive galvanometer in series with a high resistance, and then the entire instrument is connected in parallel with the circuit examined. The sensitivity of such a meter can be expressed as "ohms per volt", the number of ohms resistance in the meter circuit divided by the full scale measured value. For example, a meter with a sensitivity of 1000 ohms per volt would draw 1 milliampere at full scale voltage; if the full scale was 200 volts, the resistance at the instrument's terminals would be ohms and at full scale, the meter would draw 1 milliampere from the circuit under test. For multi-range instruments, the input resistance varies as the instrument is switched to different ranges. Moving-coil instruments with a permanent-magnet field respond only to direct current. Measurement of AC voltage requires a rectifier in the circuit so that the coil deflects in only one direction. Some moving-coil instruments are also made with the zero position in the middle of the scale instead of at one end; these are useful if the voltage reverses its polarity. Voltmeters operating on the electrostatic principle use the mutual repulsion between two charged plates to deflect a pointer attached to a spring. Meters of this type draw negligible current but are sensitive to voltages over about 100 volts and work with either alternating or direct current. ==References== ==External links== DC Metering Circuits chapter from Lessons In Electric Circuits Vol 1 DC free ebook and Lessons In Electric Circuits series.

References

  1. What is RMS Voltage · retrieved 2023-04-22 · rev 1292975770
    Cite this reference

    MLA "What is RMS Voltage." 2023-04-22. https://www.electrical4u.com/rms-or-root-mean-square-value-of-ac-signal/. Accessed 24 November 2026.

    Chicago "What is RMS Voltage." 2023-04-22. https://www.electrical4u.com/rms-or-root-mean-square-value-of-ac-signal/.

    APA encyclopegia.org. (2023). What is RMS Voltage. Retrieved November 24, 2026, from https://www.electrical4u.com/rms-or-root-mean-square-value-of-ac-signal/

  2. Andrew Kay, Pioneer in Computing, Dies at 95 · retrieved 2026-11-19 · rev 1292975770
    Cite this reference

    MLA "Andrew Kay, Pioneer in Computing, Dies at 95." Markoff, John (5 Sep 2014). 2026-11-19. https://www.nytimes.com/2014/09/06/business/andrew-kay-pioneer-in-computing-dies-at-95.html. Accessed 24 November 2026.

    Chicago "Andrew Kay, Pioneer in Computing, Dies at 95." Markoff, John (5 Sep 2014). 2026-11-19. https://www.nytimes.com/2014/09/06/business/andrew-kay-pioneer-in-computing-dies-at-95.html.

    APA Markoff, John (5 Sep 2014). (2026). Andrew Kay, Pioneer in Computing, Dies at 95. Retrieved November 24, 2026, from https://www.nytimes.com/2014/09/06/business/andrew-kay-pioneer-in-computing-dies-at-95.html

Cite this article

MLA

"Voltmeter." encyclopegia.org, 2025, https://encyclopegia.org/wiki/voltmeter. Accessed 24 November 2026.

Chicago

"Voltmeter." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/voltmeter.

APA

encyclopegia.org. (2025). Voltmeter. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/voltmeter

Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

René Laennec

enwiki · references available

Rayleigh scattering

enwiki · references available

Ron Popeil

enwiki · references available

Ray Bradbury

enwiki · references available

Ralph Cudworth

enwiki · references available

Roswell, New Mexico

enwiki · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1292975770 · 0.5 · snapshot enwiki-001292975770

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.