VVER
The water-water energetic reactor (WWER), or VVER (from ) is a series of pressurized water reactor designs developed in the Soviet Union and Russia by OKB Gidropress.[src] The name refers to the use of water as both the nuclear coolant and the neutron moderator, in a reactor intended for energy generation.[src] The idea of such a reactor was proposed at the Kurchatov Institute by Savely Moiseevich Feinberg.[src] The first prototype VVER-210 was built at the Novovoronezh Nuclear Power Plant before the 1970s, as one of two initial Soviet reactor designs (the other being the RBMK).[src] There have been several subsequent generations of VVER design, so the name is associated with substantially different reactors from original generation I to modern generation III+ designs.[src] Electrical power output ranges from 70 to 1300 MWe, with designs of up to 1700 MWe currently in development.[src] VVER power stations have been installed in Russia, Ukraine, Belarus, Armenia, China, the Czech Republic, Finland, Hungary, Slovakia, Bulgaria, India, and Iran.[src] Countries that are planning to introduce VVER reactors include Bangladesh, Egypt, Jordan, Turkey, Uzbekistan and Vietnam.[src] Germany shut down its older generation VVER reactors in 1989-90, and cancelled those under construction.[src]
The water-water energetic reactor (WWER), or VVER (from ) is a series of pressurized water reactor designs developed in the Soviet Union and Russia by OKB Gidropress.[src] The name refers to the use of water as both the nuclear coolant and the neutron moderator, in a reactor intended for energy generation.[src] The idea of such a reactor was proposed at the Kurchatov Institute by Savely Moiseevich Feinberg.[src] The first prototype VVER-210 was built at the Novovoronezh Nuclear Power Plant before the 1970s, as one of two initial Soviet reactor designs (the other being the RBMK).[src] There have been several subsequent generations of VVER design, so the name is associated with substantially different reactors from original generation I to modern generation III+ designs.[src] Electrical power output ranges from 70 to 1300 MWe, with designs of up to 1700 MWe currently in development.[src] VVER power stations have been installed in Russia, Ukraine, Belarus, Armenia, China, the Czech Republic, Finland, Hungary, Slovakia, Bulgaria, India, and Iran.[src] Countries that are planning to introduce VVER reactors include Bangladesh, Egypt, Jordan, Turkey, Uzbekistan and Vietnam.[src] Germany shut down its older generation VVER reactors in 1989-90, and cancelled those under construction.[src] ===VVER-440=== One of the earliest versions of the VVER-type, the VVER-440, manifested certain problems with its containment building design.[src] As the V-230 and older models were from the outset not built to resist a design-critical large pipe break, the manufacturer added, with the newer V-213 model, a so called Bubble condenser tower that – with its additional volume and a number of water layers – aims to suppress the forces of rapidly escaping steam without the onset of a containment-leak.[src] As a consequence, all member-countries with plants of the VVER-440 V-230 type, as well as older types, were forced by the politicians of the European Union to shut them down permanently.[src] Because of this, the Bohunice Nuclear Power Plant had to close two reactors and the Kozloduy Nuclear Power Plant had to close four.[src] Whereas in the case of the Greifswald Nuclear Power Plant, the German regulatory body had already made the same decision in the wake of the fall of the Berlin Wall.[src] ===VVER-1000=== Unit 5]] When first built, the VVER design was intended to be operational for 35 years.[src] A mid-life major overhaul including a complete replacement of critical parts such as fuel and control rod channels was thought necessary after that.[src] Since RBMK reactors specified a major replacement programme at 35 years designers originally decided this needed to happen in the VVER type as well, although they are of more robust design than the RBMK type.[src] Most of Russia's VVER plants are now reaching and passing the 35 year mark.[src] More recent design studies have allowed for an extension of lifetime up to 50 years with replacement of equipment.[src] New VVERs will be nameplated with the extended lifetime.[src] In 2010 the oldest VVER-1000, at Novovoronezh, was shut down for modernization to extend its operating life for an additional 20 years; the first to undergo such an operating life extension.[src] The work includes the modernization of management, protection and emergency systems, and improvement of security and radiation safety systems.[src] In 2018 Rosatom announced it had developed a thermal annealing technique for reactor pressure vessels which ameliorates radiation damage and extends service life by between 15 and 30 years.[src] This had been demonstrated on unit 1 of the Balakovo Nuclear Power Plant.[src] ===VVER-TOI=== The VVER-TOI ( ; , universal optimized digital) is developed from the VVER-1200.[src] It is aimed at development of typical optimized informative-advanced project of a new generation III+ Power Unit based on VVER technology, which meets a number of target-oriented parameters using modern information and management technologies.[src] The main improvements from the VVER-1200 are: power increased to 1300 MWe gross upgraded pressure vessel improved core design to improve cooling further developments of passive safety systems lower construction and operating costs with a 40-month construction time use of low-speed turbines up to 100 years service life (60 years design lifetime with 40 years of extension) In June 2019 the VVER-TOI was certified as compliant with European Utility Requirements (with certain reservations) for nuclear power plants.[src] The construction of the first two VVER-TOI units has started in 2018 and 2019 at the Kursk II Nuclear Power Plant.[src] The first VVER-TOI was connected to the grid in December 2025.[src] Kursk II-1 has entered commercial operation on May 1st 2026.[src] ===VVER-S-600=== The medium-powered VVER-S-600 is an under-development VVER technology that aims to facilitate the closure of the fuel cycle by utilizing a full load of MOX fuel.[src] Rosatom claims that this could reduce the consumption of natural uranium by 50%.[src] The letter 'S' in the name represents spectral shift control.[src] In contrast to conventional VVER technology, which utilizes a boron system for initial reactivity control for burnup and absorption, the VVER-S reactor manages control by adjusting the moderator-to-fuel ratio during operation, without relying on boron.[src] This is accomplished by taking out the water displacer rods found in designated fuel assembly channels within the core.[src] These displacers are introduced into the core at the start of the fuel cycle to lower the moderator-to-fuel ratio, thereby hardening the neutron spectrum, which enhances neutron capture in U-238 and leads to the production of Pu-239.[src] However, these displacer rods removed at the end of cycle, which softens the neutron spectrum, resulting in an increase in reactivity.[src] The VVER-S-600 is to have a design life of 80 years.[src] The estimated breeding ratio of the VVER-S-600 is 0.7 to 0.8, compared to 0.35 to 0.4 of the conventional VVERs.[src] It is expected to have a cycle length of at least 24 months using MOX fuel.[src] ==Power plants== ==Classification== ==See also== Nuclear power in Russia Russian floating nuclear power station VBER-300 ==Notes== ==References== ==External links== The VVER today, Rosatom, 2013 WWER-type reactor plants , OKB Gidropress - on AEM official pdf VVER 1200 Construction - on AEM Official YouTube Channel[src]
50 sentences · 50 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"VVER." encyclopegia.org, 2026, https://encyclopegia.org/wiki/vver. Accessed 25 November 2026.
Chicago
"VVER." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/vver.
APA
encyclopegia.org. (2026). VVER. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/vver
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON