The Y-factor method is a widely used technique for measuring the gain and noise temperature of an amplifier. It is based on the Johnson–Nyquist noise of a resistor at two different, known temperatures. Consider a microwave amplifier with a 50-ohm impedance with a 50-ohm resistor connected to the amplifier input. If the resistor is at a physical temperature T R , then the Johnson–Nyquist noise power coupled to the amplifier input is P J = k B T R B, where k B is the Boltzmann constant, and B is the bandwidth. The noise power at the output of the amplifier (i.e. the noise power coupled to an impedance-matched load that is connected to the amplifier output) is P out = Gk B (T R + T amp )B, where G is the amplifier power gain, and T amp is the amplifier noise temperature. In the Y-factor technique, P out is measured for two different, known values of T R . P out is then converted to an effective temperature T out (in units of kelvin) by dividing by k B and the measurement bandwidth B. The two values of T out are then plotted as a function of T R (also in units of kelvin), and a line is fit to these points (see figure). The slope of this line is equal to the amplifier power gain. The x intercept of the line is equal to the negative of the amplifier noise temperature −T amp in kelvins.…
The Y-factor method is a widely used technique for measuring the gain and noise temperature of an amplifier. It is based on the Johnson–Nyquist noise of a resistor at two different, known temperatures. Consider a microwave amplifier with a 50-ohm impedance with a 50-ohm resistor connected to the amplifier input. If the resistor is at a physical temperature T R , then the Johnson–Nyquist noise power coupled to the amplifier input is P J = k B T R B, where k B is the Boltzmann constant, and B is the bandwidth. The noise power at the output of the amplifier (i.e. the noise power coupled to an impedance-matched load that is connected to the amplifier output) is P out = Gk B (T R + T amp )B, where G is the amplifier power gain, and T amp is the amplifier noise temperature. In the Y-factor technique, P out is measured for two different, known values of T R . P out is then converted to an effective temperature T out (in units of kelvin) by dividing by k B and the measurement bandwidth B. The two values of T out are then plotted as a function of T R (also in units of kelvin), and a line is fit to these points (see figure). The slope of this line is equal to the amplifier power gain. The x intercept of the line is equal to the negative of the amplifier noise temperature −T amp in kelvins. The amplifier noise temperature can also be determined from the y intercept, which is equal to T amp multiplied by the gain.
References
No reference rows published for this article.
Cite this article
MLA
"Y-factor." encyclopegia.org, 2025, https://encyclopegia.org/wiki/y-factor. Accessed 24 November 2026.
Chicago
"Y-factor." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/y-factor.
APA
encyclopegia.org. (2025). Y-factor. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/y-factor
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON