encyclopegia.org

Y-factor

The Y-factor method is a widely used technique for measuring the gain and noise temperature of an amplifier. It is based on the Johnson–Nyquist noise of a resistor at two different, known temperatures. Consider a microwave amplifier with a 50-ohm impedance with a 50-ohm resistor connected to the amplifier input. If the resistor is at a physical temperature T R , then the Johnson–Nyquist noise power coupled to the amplifier input is P J = k B T R B, where k B is the Boltzmann constant, and B is the bandwidth. The noise power at the output of the amplifier (i.e. the noise power coupled to an impedance-matched load that is connected to the amplifier output) is P out = Gk B (T R + T amp )B, where G is the amplifier power gain, and T amp is the amplifier noise temperature. In the Y-factor technique, P out is measured for two different, known values of T R . P out is then converted to an effective temperature T out (in units of kelvin) by dividing by k B and the measurement bandwidth B. The two values of T out are then plotted as a function of T R (also in units of kelvin), and a line is fit to these points (see figure). The slope of this line is equal to the amplifier power gain. The x intercept of the line is equal to the negative of the amplifier noise temperature −T amp in kelvins.…

The Y-factor method is a widely used technique for measuring the gain and noise temperature of an amplifier. It is based on the Johnson–Nyquist noise of a resistor at two different, known temperatures. Consider a microwave amplifier with a 50-ohm impedance with a 50-ohm resistor connected to the amplifier input. If the resistor is at a physical temperature T R , then the Johnson–Nyquist noise power coupled to the amplifier input is P J = k B T R B, where k B is the Boltzmann constant, and B is the bandwidth. The noise power at the output of the amplifier (i.e. the noise power coupled to an impedance-matched load that is connected to the amplifier output) is P out = Gk B (T R + T amp )B, where G is the amplifier power gain, and T amp is the amplifier noise temperature. In the Y-factor technique, P out is measured for two different, known values of T R . P out is then converted to an effective temperature T out (in units of kelvin) by dividing by k B and the measurement bandwidth B. The two values of T out are then plotted as a function of T R (also in units of kelvin), and a line is fit to these points (see figure). The slope of this line is equal to the amplifier power gain. The x intercept of the line is equal to the negative of the amplifier noise temperature −T amp in kelvins. The amplifier noise temperature can also be determined from the y intercept, which is equal to T amp multiplied by the gain.

References

No reference rows published for this article.

Cite this article

MLA

"Y-factor." encyclopegia.org, 2025, https://encyclopegia.org/wiki/y-factor. Accessed 24 November 2026.

Chicago

"Y-factor." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/y-factor.

APA

encyclopegia.org. (2025). Y-factor. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/y-factor

Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

vascular endothelial growth factor

stub · references available

growth factor receptor

stub · references available

view factor

stub · references available

X Factor

stub · references available

Boltzmann factor

stub · references available

Variance inflation factor

stub · references available

cobalamin binding intrinsic factor

stub · references available

hypoxia-inducible factor

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1305556210 · 0.5 · snapshot enwiki-001305556210

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.