Accuracy class

Uses your system voice; voice and rate in settings.

Snapshot

≈ 3 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Accuracy classes are defined and used in IEC and ANSI standards. Classes are denoted by either a letter or percentage. For example, Class B is a temperature accuracy from IEC-751 that requires accuracy of ± 0.15 degrees Celsius. Class 0.5 is an ANSI C12.20 accuracy class for electric meters with absolute accuracy better than ± 0.5% of the nominal full scale reading. Typically, a class specifies accuracy at a number of points, with the absolute accuracy at lower values being better than the nominal "percentage of full scale" accuracy. Accuracy classes such as IEC's 0.15s are a 'special' high accuracy class. Calculation for accuracy of class 1 meter: 1600 impulse/KWh and considering, P.F= 1 and LOAD = 100w Revolution time, Rt = (3600×Kh×1)/Load(w) [Kh = 1000/(impulse/Kwh=1600)] Rt = (3600×0.625×1)/100 Rt = 22.5sec [Standard] %of error = (Ft-Rt)/Rt The positive or negative result indicates whether the meter is fast or slow. If the result is positive, then the meter is fast, while negative means the meter is slow.

Accuracy classes are defined and used in IEC and ANSI standards. Classes are denoted by either a letter or percentage. For example, Class B is a temperature accuracy from IEC-751 that requires accuracy of ± 0.15 degrees Celsius. Class 0.5 is an ANSI C12.20 accuracy class for electric meters with absolute accuracy better than ± 0.5% of the nominal full scale reading. Typically, a class specifies accuracy at a number of points, with the absolute accuracy at lower values being better than the nominal "percentage of full scale" accuracy. Accuracy classes such as IEC's 0.15s are a 'special' high accuracy class. Calculation for accuracy of class 1 meter: 1600 impulse/KWh and considering, P.F= 1 and LOAD = 100w Revolution time, Rt = (3600×Kh×1)/Load(w) [Kh = 1000/(impulse/Kwh=1600)] Rt = (3600×0.625×1)/100 Rt = 22.5sec [Standard] %of error = (Ft-Rt)/Rt The positive or negative result indicates whether the meter is fast or slow. If the result is positive, then the meter is fast, while negative means the meter is slow.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1236053007 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

2 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.