Lesson plan

Cunningham correction factor

In fluid dynamics, the Cunningham correction factor, or Cunningham slip correction factor (denoted ), is used to account for non-continuum effects when calculating the drag on small particles. The derivation of Stokes' law, which is used to calculate the drag force on small particles, assumes a no-slip condition which is no longer correct at high Knudsen numbers. The Cunningham slip correction factor allows predicting the drag force on a particle moving a fluid with Knudsen number between the continuum regime and free molecular flow. The drag coefficient calculated with standard correlations is divided by the Cunningham correction factor, , given below. Ebenezer Cunningham derived the correction factor in 1910 and with Robert Andrews Millikan, verified the correction in the same year. : C = 1+ \frac{2\lambda}{d} \left(A_1+A_2 e^{\frac{-A_3 d}{\lambda}} \right) where * is the correction factor * is the mean free path * is the particle diameter * are experimentally determined coefficients. :For air (Davies, 1945): ::A 1 = 1.257 ::A 2 = 0.400 ::A 3 = 0.55 The Cunningham correction factor becomes significant when particles become smaller than 15 micrometers, for air at ambient conditions. For sub-micrometer particles, Brownian motion must be taken into account.

Back to article

Article summary

In fluid dynamics, the Cunningham correction factor, or Cunningham slip correction factor (denoted ), is used to account for non-continuum effects when calculating the drag on small particles. The derivation of Stokes' law, which is used to calculate the drag force on small particles, assumes a no-slip condition which is no longer correct at high Knudsen numbers. The Cunningham slip correction factor allows predicting the drag force on a particle moving a fluid with Knudsen number between the continuum regime and free molecular flow. The drag coefficient calculated with standard correlations is divided by the Cunningham correction factor, , given below. Ebenezer Cunningham derived the correction factor in 1910 and with Robert Andrews Millikan, verified the correction in the same year. : C = 1+ \frac{2\lambda}{d} \left(A_1+A_2 e^{\frac{-A_3 d}{\lambda}} \right) where * is the correction factor * is the mean free path * is the particle diameter * are experimentally determined coefficients. :For air (Davies, 1945): ::A 1 = 1.257 ::A 2 = 0.400 ::A 3 = 0.55 The Cunningham correction factor becomes significant when particles become smaller than 15 micrometers, for air at ambient conditions. For sub-micrometer particles, Brownian motion must be taken into account.

Key claims

No claims recorded.

Discussion questions

  1. Summarise the article in your own words. Which single claim would you verify first, and why?
  2. Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
  3. If two sources disagreed about one of these facts, what would you need in order to trust one over the other?

Bibliography

No sources recorded.

Key claims and bibliography are generated from the same tracked claims and sources as the article page.