with a 5 mM Fe redox couple reacting with a graphite electrode in 1M potassium nitrate solution. and denote the corresponding electrode potentials (vs. Ag/AgCl) of maximal reaction rates. For an ideal reversible (Nernstian) reaction the theoretical peak separation (E PA - E PC ) is 57 mV. In electrochemistry, cyclic voltammetry (CV) is a type of voltammetric measurement where the potential of the working electrode is ramped linearly versus time.
Unlike in linear sweep voltammetry, after the set potential is reached in a CV experiment, the working electrode's potential is ramped in the opposite direction to return to the initial potential. These cycles in potential are repeated until the voltammetric trace reaches a cyclic steady state. The current at the working electrode is plotted versus the voltage at the working electrode to yield the cyclic voltammogram (see Figure 1).
Cyclic voltammetry is generally used to study the electrochemical properties of an analyte in solution or of a molecule that is adsorbed onto the electrode and to quantify electrochemical surface area of catalysts in electrochemical cells.
with a 5 mM Fe redox couple reacting with a graphite electrode in 1M potassium nitrate solution. and denote the corresponding electrode potentials (vs. Ag/AgCl) of maximal reaction rates. For an ideal reversible (Nernstian) reaction the theoretical peak separation (E PA - E PC ) is 57 mV. ]] In electrochemistry, cyclic voltammetry (CV) is a type of voltammetric measurement where the potential of the working electrode is ramped linearly versus time.
Unlike in linear sweep voltammetry, after the set potential is reached in a CV experiment, the working electrode's potential is ramped in the opposite direction to return to the initial potential. These cycles in potential are repeated until the voltammetric trace reaches a cyclic steady state. The current at the working electrode is plotted versus the voltage at the working electrode to yield the cyclic voltammogram (see Figure 1).
Cyclic voltammetry is generally used to study the electrochemical properties of an analyte in solution or of a molecule that is adsorbed onto the electrode and to quantify electrochemical surface area of catalysts in electrochemical cells.
The analyte is in solution
Reversible couples
Often the analyte displays a reversible CV wave (such as that depicted in Figure 1), which is observed when all of the initial analyte can be recovered after a forward and reverse scan cycle. Although such reversible couples are simpler to analyze, they contain less information than more complex waveforms. The waveform of even reversible couples is complex owing to the combined effects of polarization and diffusion.
The difference between the two peak potentials (E p ), ΔE p , is of particular interest. ΔE p = E pa - E pc > 0 This difference mainly results from the effects of analyte diffusion rates. In the ideal case of a reversible 1e- couple (i.e., Nernstian), ΔE p is 57 mV and the full-width half-max of the forward scan peak is 59 mV. Typical values observed experimentally are greater, often approaching 70 or 80 mV. The waveform is also affected by the rate of electron transfer, usually discussed as the activation barrier for electron transfer.
A theoretical description of polarization overpotential is in part described by the Butler–Volmer equation and Cottrell equation. In an ideal system the relationship reduces to E_{pa}-E_{pc}=\frac{56.5\text{ mV}}{n} for an n electron process. Focusing on current, reversible couples are characterized by i pa /i pc = 1. When a reversible peak is observed, thermodynamic information in the form of a half cell potential E 0 1/2 can be determined.
When waves are semi-reversible (i pa /i pc is close but not equal to 1), it may be possible to determine even more specific information (see electrochemical reaction mechanism). The current maxima for oxidation and reduction itself depend on the scan rate, see the figure.
To study the nature of the electrochemical reaction mechanism it is useful to perform a power fit according to j_{max}^{\;ox,read} = j_{0} + A \cdot \bigg(\frac{scan\,rate}{mV/s}\bigg)^{x} A fit with x= 0.5 in the figure shows the proportionality of the peak currents to the square root of the scan rate when additionally \mathrm{ j_{0} is fulfilled. This leads to the so-called Randles–Sevcik equation and the rate determining step of this electrochemical redox reaction can be assigned to diffusion.
Nonreversible couples
Many redox processes observed by CV are quasi-reversible or non-reversible. In such cases the thermodynamic potential E 0 1/2 is often deduced by simulation. The irreversibility is indicated by i pa /i pc ≠ 1. Deviations from unity are attributable to a subsequent chemical reaction that is triggered by the electron transfer. Such EC processes can be complex, involving isomerization, dissociation, association, etc.
The cell
A standard CV experiment employs a cell fitted with three electrodes: reference electrode, working electrode, and counter electrode. This combination is sometimes referred to as a three-electrode setup. Electrolyte is usually added to the sample solution to ensure sufficient conductivity. The solvent, electrolyte, and material composition of the working electrode will determine the potential range that can be accessed during the experiment. The electrodes are immobile and sit in unstirred solutions during cyclic voltammetry.
This "still" solution method gives rise to cyclic voltammetry's characteristic diffusion-controlled peaks. This method also allows a portion of the analyte to remain after reduction or oxidation so that it may display further redox activity. Stirring the solution between cyclic voltammetry traces is important in order to supply the electrode surface with fresh analyte for each new experiment.
The solubility of an analyte can change drastically with its overall charge; as such it is common for reduced or oxidized analyte species to precipitate out onto the electrode. This layering of analyte can insulate the electrode surface, display its own redox activity in subsequent scans, or otherwise alter the electrode surface in a way that affects the CV measurements. For this reason it is often necessary to clean the electrodes between scans. Common materials for the working electrode include glassy carbon, platinum, and gold.
These electrodes are generally encased in a rod of inert insulator with a disk exposed at one end. A regular working electrode has a radius within an order of magnitude of 1 mm. Having a controlled surface area with a well-defined shape is necessary for being able to interpret cyclic voltammetry results. To run cyclic voltammetry experiments at very high scan rates a regular working electrode is insufficient. High scan rates create peaks with large currents and increased resistances, which result in distortions.
Ultramicroelectrodes can be used to minimize the current and resistance. The counter electrode, also known as the auxiliary or second electrode, can be any material that conducts current easily, will not react with the bulk solution, and has a surface area much larger than the working electrode. Common choices are platinum and graphite. Reactions occurring at the counter electrode surface are unimportant as long as it continues to conduct current well.
To maintain the observed current the counter electrode will often oxidize or reduce the solvent or bulk electrolyte.
Solvents
CV can be conducted using a variety of solutions. Solvent choice for cyclic voltammetry takes into account several requirements. The solvent must dissolve the analyte and high concentrations of the supporting electrolyte. It must also be stable in the potential window of the experiment with respect to the working electrode. It must not react with either the analyte or the supporting electrolyte. It must be pure to prevent interference.
Electrolyte
The electrolyte ensures good electrical conductivity and minimizes iR drop such that the recorded potentials correspond to actual potentials. For aqueous solutions, many electrolytes are available, but typical ones are alkali metal salts of perchlorate and nitrate. In nonaqueous solvents, the range of electrolytes is more limited, and a popular choice is tetrabutylammonium hexafluorophosphate.
Evaluation of a technique
The technique being evaluated uses voltammetric sensors combined in an electronic tongue (ET) to observe the antioxidant capacity in red wines. These electronic tongues (ETs) consist of multiple sensing units like voltammetric sensors, which will have unique responses to certain compounds. This approach is optimal to use since samples of high complexity can be analyzed with high cross-selectivity. Thus, the sensors can be sensitive to pH and antioxidants.
As usual, the voltage in the cell was monitored using a working electrode and a reference electrode (silver/silver chloride electrode). Furthermore, a platinum counter electrode allows the current to continue to flow during the experiment. The Carbon Paste Electrodes sensor (CPE) and the Graphite-Epoxy Composite (GEC) electrode are tested in a saline solution before the scanning of the wine so that a reference signal can be obtained. The wines are then ready to be scanned, once with CPE and once with GEC.
While cyclic voltammetry was successfully used to generate currents using the wine samples, the signals were complex and needed an additional extraction stage. It was found that the ET method could successfully analyze wine's antioxidant capacity as it agreed with traditional methods like TEAC, Folin-Ciocalteu, and I280 indexes. Additionally, the time was reduced, the sample did not have to be pretreated, and other reagents were unnecessary, all of which diminished the popularity of traditional methods.
Thus, cyclic voltammetry successfully determines the antioxidant capacity and even improves previous results.
Antioxidant capacity of chocolate and hops
The phenolic antioxidants for cocoa powder, dark chocolate, and milk chocolate can also be determined via cyclic voltammetry. In order to achieve this, the anodic peaks are calculated and analyzed with the knowledge that the first and third anodic peaks can be assigned to the first and second oxidation of flavonoids, while the second anodic peak represents phenolic acids. Using the graph produced by cyclic voltammetry, the total phenolic and flavonoid content can be deduced in each of the three samples.
It was observed that cocoa powder and dark chocolate had the highest antioxidant capacity since they had high total phenolic and flavonoid content. Milk chocolate had the lowest capacity as it had the lowest phenolic and flavonoid content. While the antioxidant content was given using the cyclic voltammetry anodic peaks, HPLC must then be used to determine the purity of catechins and procyanidin in cocoa powder, dark chocolate, and milk chocolate.
Hops, the flowers used in making beer, contain antioxidant properties due to the presence of flavonoids and other polyphenolic compounds. In this cyclic voltammetry experiment, the working electrode voltage was determined using a ferricinium/ferrocene reference electrode. By comparing different hop extract samples, it was observed that the sample containing polyphenols that were oxidized at less positive potentials proved to have better antioxidant capacity.