Lesson plan
Cyclic voltammetry
with a 5 mM Fe redox couple reacting with a graphite electrode in 1M potassium nitrate solution. and denote the corresponding electrode potentials (vs. Ag/AgCl) of maximal reaction rates. For an ideal reversible (Nernstian) reaction the theoretical peak separation (E PA - E PC ) is 57 mV. In electrochemistry, cyclic voltammetry (CV) is a type of voltammetric measurement where the potential of the working electrode is ramped linearly versus time. Unlike in linear sweep voltammetry, after the set potential is reached in a CV experiment, the working electrode's potential is ramped in the opposite direction to return to the initial potential. These cycles in potential are repeated until the voltammetric trace reaches a cyclic steady state. The current at the working electrode is plotted versus the voltage at the working electrode to yield the cyclic voltammogram (see Figure 1). Cyclic voltammetry is generally used to study the electrochemical properties of an analyte in solution or of a molecule that is adsorbed onto the electrode and to quantify electrochemical surface area of catalysts in electrochemical cells.
Article summary
with a 5 mM Fe redox couple reacting with a graphite electrode in 1M potassium nitrate solution. and denote the corresponding electrode potentials (vs. Ag/AgCl) of maximal reaction rates. For an ideal reversible (Nernstian) reaction the theoretical peak separation (E PA - E PC ) is 57 mV. In electrochemistry, cyclic voltammetry (CV) is a type of voltammetric measurement where the potential of the working electrode is ramped linearly versus time. Unlike in linear sweep voltammetry, after the set potential is reached in a CV experiment, the working electrode's potential is ramped in the opposite direction to return to the initial potential. These cycles in potential are repeated until the voltammetric trace reaches a cyclic steady state. The current at the working electrode is plotted versus the voltage at the working electrode to yield the cyclic voltammogram (see Figure 1). Cyclic voltammetry is generally used to study the electrochemical properties of an analyte in solution or of a molecule that is adsorbed onto the electrode and to quantify electrochemical surface area of catalysts in electrochemical cells.
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.