Lesson plan

Diversity factor

In the context of electricity, the diversity factor is the ratio of the sum of the individual non-coincident maximum loads of various subdivisions of the system to the maximum demand of the complete system. It is a way to quantify the diversity among consumer classes. : f_\text{Diversity} = \frac{\sum\limits_{i=1}^n\text{Individual peak load}_i}{\sum\limits_{i=1}^n\text{Max}(\text{Aggregated load}_i)} The diversity factor is always greater than 1. The aggregate load \left( \sum\limits_{i=1}^n\text{Aggregated load}_i \right) is time dependent as well as being dependent upon equipment characteristics. The diversity factor recognizes that the whole load does not equal the sum of its parts due to this time interdependence or "diversity." For example, one might have ten air conditioning units that are 20 tons each at a facility with an average full load equivalent operating hours of 2000 hours per year. However, since the units are each thermostatically controlled, it is not known exactly when each unit turns on. If the ten units are substantially larger than the facility's actual peak AC load, then fewer than all ten units will likely come on at once. Thus, even though each unit runs a total of a couple of thousand (2000) hours a year, they do not all come on at the same time to affect the facility's peak load.…

Back to article

Article summary

In the context of electricity, the diversity factor is the ratio of the sum of the individual non-coincident maximum loads of various subdivisions of the system to the maximum demand of the complete system. It is a way to quantify the diversity among consumer classes. : f_\text{Diversity} = \frac{\sum\limits_{i=1}^n\text{Individual peak load}_i}{\sum\limits_{i=1}^n\text{Max}(\text{Aggregated load}_i)} The diversity factor is always greater than 1. The aggregate load \left( \sum\limits_{i=1}^n\text{Aggregated load}_i \right) is time dependent as well as being dependent upon equipment characteristics. The diversity factor recognizes that the whole load does not equal the sum of its parts due to this time interdependence or "diversity." For example, one might have ten air conditioning units that are 20 tons each at a facility with an average full load equivalent operating hours of 2000 hours per year. However, since the units are each thermostatically controlled, it is not known exactly when each unit turns on. If the ten units are substantially larger than the facility's actual peak AC load, then fewer than all ten units will likely come on at once. Thus, even though each unit runs a total of a couple of thousand (2000) hours a year, they do not all come on at the same time to affect the facility's peak load.…

Key claims

No claims recorded.

Discussion questions

  1. Summarise the article in your own words. Which single claim would you verify first, and why?
  2. Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
  3. If two sources disagreed about one of these facts, what would you need in order to trust one over the other?

Bibliography

No sources recorded.

Key claims and bibliography are generated from the same tracked claims and sources as the article page.