Ground (electricity)

In electrical engineering, ground or earth may refer to reference ground – a reference point in an electrical circuit from which voltages are measured, earth ground – an electrically neutral node that has a lot of available charges (e.g.…

Uses your system voice; voice and rate in settings.

Snapshot

≈ 10 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

In electrical engineering, ground or earth may refer to reference ground – a reference point in an electrical circuit from which voltages are measured, earth ground – an electrically neutral node that has a lot of available charges (e.g. the physical ground of Earth), or common ground – a common return path for electric current (also called neutral in electric power systems). Ground current or earth current is the current that flows through a reference ground, earth ground, or common ground.

To ground or to earth an object is to electrically connect the object to a reference ground, earth ground, or common ground. Electrical circuits may be grounded for several reasons.

A protective earth conductor (PE conductor) is a conductor that is used for electrical bonding, that is, connecting an electrical equipment from its exposed and conductive but normally unenergized part to common ground. If the conductor is a wire, it is also called ground wire or earth wire.

Ground wire is often used for lower voltage systems and is often colored green, or green and yellow, per standard. Electrical bonding can protect users from electrical shock hazards. If internal insulation fails and the equipment is turned on, the exposed conductive parts may have dangerous voltages.…

In electrical engineering, ground or earth may refer to reference ground – a reference point in an electrical circuit from which voltages are measured, earth ground – an electrically neutral node that has a lot of available charges (e.g. the physical ground of Earth), or common ground – a common return path for electric current (also called neutral in electric power systems). Ground current or earth current is the current that flows through a reference ground, earth ground, or common ground.

To ground or to earth an object is to electrically connect the object to a reference ground, earth ground, or common ground. Electrical circuits may be grounded for several reasons.

A protective earth conductor (PE conductor) is a conductor that is used for electrical bonding, that is, connecting an electrical equipment from its exposed and conductive but normally unenergized part to common ground. If the conductor is a wire, it is also called ground wire or earth wire.

Ground wire is often used for lower voltage systems and is often colored green, or green and yellow, per standard. Electrical bonding can protect users from electrical shock hazards. If internal insulation fails and the equipment is turned on, the exposed conductive parts may have dangerous voltages.

Connection of exposed conductive parts to a PE conductor provides a low-impedance path for current to flow back to the incoming neutral. This results in a fault and allows circuit breakers (or RCDs) to interrupt power supply. The current that flows through the low-impedance path is high and will usually trip the breaker or melt the safety fuse if any.

Even if the circuit does not break due to failures, the current still only flows mainly through the PE conductor instead of the user upon touching the exposed conductive part. A PE conductor is an essential part of the safety provided by the earthing system. A safety ground is a loose term that refers to a common ground that is used for safety purposes.

Connection to earth ground limits the build-up of static electricity. This connection is crucial for safety when handling flammable products or electrostatic-sensitive devices. In a large-scale electrical system, a piece of conducting material, called grounding electrode or earthing electrode, is buried in the soil to act as an earth ground.

A grounding electrode conductor or ground conductor is a conductor that connects an electrical equipment to the grounding electrode. In some telegraph and power transmission circuits, the physical ground (an earth ground) itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return and earth-return telegraph).

In an electric power system, the neutral is connected to earth ground, close to the point of entry. For measurement purposes, the ground of the Earth, having a reasonably constant potential, serves as a reference ground against which other potentials can be measured.

An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. Circuits in portable electronic devices, such as cell phones and media players, as well as circuits in vehicles, have a reference ground (also called chassis ground in those cases).

In electronic circuit theory, a signal ground is the common ground and reference ground for electric signal; and a power ground is the common ground for power current. The signal ground and power ground may be connected.

There is usually a large conductor attached to one side of the power supply (such as the "ground plane" on a printed circuit board), which serves as the common ground, the common return path for current from many different components in the circuit. The signal ground and power ground are usually assumed to be an earth ground and idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential.

Where a physical ground connection has a significant resistance, the approximation of zero potential is no longer valid (no longer a valid reference ground). Stray voltages or earth potential rise effects will occur, which may create noise in signals or produce an electric shock hazard if large enough. |- align = "center" | |width = "25"| | |width = "25"| | |- align = "center" | Signal ground | | Chassis ground | | Earth ground Signal grounds serve as return paths for signals and power (at extra-low voltages, less than about 50 V) within equipment, and on the signal interconnections between equipment.

Many electronic designs feature a single return that acts as a reference for all signals. Power and signal grounds often get connected, usually through the metal case of the equipment.

Designers of printed circuit boards must take care in the layout of electronic systems so that high-power or rapidly switching currents in one part of a system do not inject noise into low-level sensitive parts of a system due to some common impedance in the grounding traces of the layout.

Radio frequency ground

Certain types of radio antennas (or their feedlines) require a connection to ground that functions adequately at radio frequencies. This type of ground is called a radio frequency ground.

In general, a radio transmitter, its power source, and its antenna will require three functionally different grounds: A lightning safety ground (perhaps several) that discharges lightning strikes on an outdoor antenna, and separately one that diverts residual strike current from entering the house / radio shack / radio equipment An electrical power safety ground, provided by the ground connection at the electrical outlet A radio frequency ground that establishes a low-resistance return path for the electrical field produced by the antenna during the process of creating radiated waves. Although some of these grounds might be combined, and should be connected at exactly one point, only the last type of ground is covered in this section.

Lightning safety grounding (1) is covered in the following section, not here. The electrical safety ground (2) was discussed in previous sections and is unsuitable for radio purposes, although required for the power supply. The radio frequency ground (3) is the topic of this section.

Since the radio frequencies of the current in antennas are far higher than the 50 or 60 Hz frequency of the power line, radio grounding systems use different principles than AC power grounding. The "protective earth" (PE) safety ground wires in AC utility building wiring were not designed for, and cannot be used as an adequate substitute for an RF ground.

The long utility ground wires have high impedance at certain frequencies. In the case of a transmitter, the RF current flowing through the ground wires can radiate radio frequency interference and induce hazardous voltages on grounded metal parts of other appliances, so separate ground systems are used.

Monopole antennas operating at lower frequencies, below 20 MHz, use the surface of the Earth as a part of the antenna, as a conductive plane to reflect the radio waves and provide a return path for electric fields extending from the antenna. Types of earth-grounded monopoles include the mast radiator used by AM radio stations, the 'T' and inverted 'L' antenna, and umbrella antenna.

The feedline from the transmitter is connected between the antenna and ground, so it requires a grounding (earthing) system under the antenna to make contact with the soil to collect the return current. The ground system also functions as a capacitor plate, to receive the displacement current from the antenna and return it to the ground side of the transmitter's feedline, so it is preferably located directly under the antenna.

In receivers and low efficiency / low power transmitters, the ground connection can be as simple as one or several metal rods or stakes driven into the soil, or an electrical connection to a building's metal water piping which extends into the earth. However, in transmitting antennas the ground system carries the full output current of the transmitter, so the resistance of an inadequate ground contact can be a major loss of transmitter power.

Medium to high power transmitters usually have an extensive ground system consisting of bare copper cables buried in the earth under the antenna, to lower resistance. Since for the omnidirectional antennas used on these bands the Earth currents travel radially toward the ground point from all directions, the grounding system usually consists of a radial pattern of buried cables extending outward under the antenna in all directions, connected together to the ground side of the transmitter's feedline at a terminal next to the base of the antenna called a radial ground system.

The transmitter power lost in the ground resistance, and so the efficiency of the antenna, depends on the soil conductivity. This varies widely; marshy ground or ponds, particularly salt water, provide the lowest resistance ground, while dry rocky or sandy soil are the highest.

The power loss per square meter in the ground is proportional to the square of the transmitter current density flowing in the earth. The current density, and power dissipated, increases the closer one gets to the ground terminal at the base of the antenna, so the radial ground system can be thought of as providing a higher conductivity medium, copper, for the ground current to flow through, in the parts of the ground carrying high current density, to reduce power losses.

References

Federal Standard 1037C in support of MIL-STD-188

Text derived from https://en.wikipedia.org/w/index.php?oldid=1376325747 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

16 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.