OD600 (Also written as O.D. 600, D 600 , o.d. 600, OD 600 ) is an abbreviation indicating the optical density of a sample measured at a wavelength of 600 nm in 1 cm light path (unless otherwise stated). It is a commonly used in microbiology for estimating the concentration of bacteria or other cells in a liquid as the 600 nm wavelength does little to damage or hinder their growth. OD 600 is a type of turbidity measurement. Since optical density in case of OD 600 measurements results from light scattering by particles (cells) rather than absorption, size and shape as well as dead cells and debris of a cell may add to light dissipating. Distinctive cell types that are at densities of the same level (eg. cell/mL), may, therefore, show varying values OD 600 , when estimated on a similar instrument. For turbid samples such as cell cultures, the major contributor for the optical density measured is light scattering and not the result of molecular absorption following the Beer-Lambert Law. The measurements are therefore depending on the optical setup of the spectrophotometer (distance between the cell holder and instrument exit slit, monochromator optics, slit geometry, etc.), different instrument types will most likely tend to give different OD 600 readings for the same turbid sample. Measuring the change of the OD 600 as a function of time (e.g.…

OD600 (Also written as O.D. 600, D 600 , o.d. 600, OD 600 ) is an abbreviation indicating the optical density of a sample measured at a wavelength of 600 nm in 1 cm light path (unless otherwise stated). It is a commonly used in microbiology for estimating the concentration of bacteria or other cells in a liquid as the 600 nm wavelength does little to damage or hinder their growth. OD 600 is a type of turbidity measurement. Since optical density in case of OD 600 measurements results from light scattering by particles (cells) rather than absorption, size and shape as well as dead cells and debris of a cell may add to light dissipating. Distinctive cell types that are at densities of the same level (eg. cell/mL), may, therefore, show varying values OD 600 , when estimated on a similar instrument. For turbid samples such as cell cultures, the major contributor for the optical density measured is light scattering and not the result of molecular absorption following the Beer-Lambert Law. The measurements are therefore depending on the optical setup of the spectrophotometer (distance between the cell holder and instrument exit slit, monochromator optics, slit geometry, etc.), different instrument types will most likely tend to give different OD 600 readings for the same turbid sample. Measuring the change of the OD 600 as a function of time (e.g. measuring of the growth curve) may indicate the growth phase of cultured cell population, i.e. whether it is in the lag phase, log phase, or stationary phase. For protein expression and purification in bacteria it is recommended that protein induction and cell harvesting should be done at specific OD 600 (usually at the end of the log phase, OD 600  = 0.4). OD 600 is preferable to UV spectroscopy when measuring the growth over time of a cell population because at this wavelength, the cells will not be killed as they would under too much UV radiation. UV radiation has also been shown to cause small to medium-sized mutations in bacteria, potentially altering or destroying genes of interest.

References

Text derived from https://en.wikipedia.org/w/index.php?oldid=1320878916 under CC BY-SA 4.0; modifications have been made.

Provenance

snapshot od600-797144-c0fcbdd134abdb05 · hash c0fcbdd134abdb05a4dea75e2f34e6307490edbb71dca624d7065511d0126afa · captured 1762500485.0 · version history

Cite this page as: encyclopegia.org, “OD600”, snapshot od600-797144-c0fcbdd134abdb05. https://encyclopegia.org/a/od600

Sources cited in this revision

Extracted from the cited revision's reference blocks; absent citations are not invented.