Specific detectivity, or D*, for a photodetector is a figure of merit used to characterize performance, equal to the reciprocal of noise-equivalent power (NEP), normalized per square root of the sensor's area and frequency bandwidth (reciprocal of twice the integration time). Specific detectivity is given by D^*=\frac{\sqrt{A}}{NEP} , where A is the area of the photosensitive region of the detector, and NEP the noise equivalent power (in units of W/\sqrt{Hz} ) . It is commonly expressed in Jones units ( cm \cdot \sqrt{Hz}/ W ) in honor of Robert Clark Jones who originally defined it. Given that noise-equivalent power can be expressed as a function of the responsivity \mathfrak{R} (in units of A/W or V/W ) and the noise spectral density S_n (in units of A/Hz^{1/2} or V/Hz^{1/2} ) as NEP=\frac{S_n}{\mathfrak{R}} , it is common to see the specific detectivity expressed as D^*=\frac{\mathfrak{R}\cdot\sqrt{A}}{S_n} . It is often useful to express the specific detectivity in terms of relative noise levels present in the device. A common expression is given below.…
Specific detectivity, or D*, for a photodetector is a figure of merit used to characterize performance, equal to the reciprocal of noise-equivalent power (NEP), normalized per square root of the sensor's area and frequency bandwidth (reciprocal of twice the integration time). Specific detectivity is given by D^*=\frac{\sqrt{A}}{NEP} , where A is the area of the photosensitive region of the detector, and NEP the noise equivalent power (in units of W/\sqrt{Hz} ) . It is commonly expressed in Jones units ( cm \cdot \sqrt{Hz}/ W ) in honor of Robert Clark Jones who originally defined it. Given that noise-equivalent power can be expressed as a function of the responsivity \mathfrak{R} (in units of A/W or V/W ) and the noise spectral density S_n (in units of A/Hz^{1/2} or V/Hz^{1/2} ) as NEP=\frac{S_n}{\mathfrak{R}} , it is common to see the specific detectivity expressed as D^*=\frac{\mathfrak{R}\cdot\sqrt{A}}{S_n} . It is often useful to express the specific detectivity in terms of relative noise levels present in the device. A common expression is given below. D^* = \frac{q\lambda \eta}{hc} \left[\frac{4kT}{R_0 A}+2q^2 \eta \Phi_b\right]^{-1/2} With q as the electronic charge, \lambda is the wavelength of interest, h is the Planck constant, c is the speed of light, k is the Boltzmann constant, T is the temperature of the detector, R_0A is the zero-bias dynamic resistance area product (often measured experimentally, but also expressible in noise level assumptions), \eta is the quantum efficiency of the device, and \Phi_b is the total flux of the source (often a blackbody) in photons/s/cm 2 . \Delta f = \frac{1}{2 t_c} Next, an average signal and rms noise needs to be measured from a set of N frames. This is done either directly by the instrument, or done as post-processing. \text{Signal}_{\text{avg}} = \frac{1}{N}\big( \sum_i^{N} \text{Signal}_i \big) \text{Noise}_{\text{rms}} = \sqrt{\frac{1}{N}\sum_i^N (\text{Signal}_i - \text{Signal}_{\text{avg}})^2} with the NEP=\frac{\text{Noise}_{rms}}{\sqrt{\Delta f}} . Now, the computation of the radiance H in W/sr/cm 2 must be computed where cm 2 is the emitting area. Next, emitting area must be converted into a projected area and the solid angle; this product is often called the etendue. This step can be obviated by the use of a calibrated source, where the exact number of photons/s/cm 2 is known at the detector. If this is unknown, it can be estimated using the black-body radiation equation, detector active area A_d and the etendue. This ultimately converts the outgoing radiance of the black body in W/sr/cm 2 of emitting area into one of W observed on the detector. The broad-band responsivity, is then just the signal weighted by this wattage. R = \frac{\text{Signal}_{\text{avg}}}{H G} = \frac{\text{Signal}_{\text{avg}}}{\int dH dA_d d\Omega_{BB}}, where R is the responsivity in units of Signal / W, (or sometimes V/W or A/W), H is the outgoing radiance from the black body (or light source) in W/sr/cm 2 of emitting area, G is the total integrated etendue between the emitting source and detector surface, A_d is the detector area, \Omega_{BB} is the solid angle of the source projected along the line connecting it to the detector surface. From this metric noise-equivalent power can be computed by taking the noise level over the responsivity. \text{NEP} = \frac{\text{Noise}_{\text{rms}}}{R \sqrt{\Delta f}} = \frac{\text{Noise}_{\text{rms}}}{\text{Signal}_{\text{avg}}}\frac{H G}{\sqrt{\Delta f}} Similarly, noise-equivalent irradiance can be computed using the responsivity in units of photons/s/W instead of in units of the signal. Now, the detectivity is simply the noise-equivalent power normalized to the bandwidth and detector area. D^* = \frac{\sqrt{A_d}}{\text{NEP}} = \frac{\sqrt{\Delta f A_d}}{H G} \frac{\text{Signal}_{\text{avg}}}{\text{Noise}_{\text{rms}}}
Text derived from https://en.wikipedia.org/w/index.php?oldid=1372315522 under CC BY-SA 4.0; modifications have been made.